![F5 BIG-IP 10000 Series Platform Manual Download Page 23](http://html.mh-extra.com/html/f5/big-ip-10000-series/big-ip-10000-series_platform-manual_535200023.webp)
Description
Option
Letter
Configures the baud speed for connecting to AOM using the serial
console. Select from these options:
Set console baud rate
B
•
9600
•
19200 (default)
•
38400
•
57600
•
115200
Displays information about the AOM firmware and bootloader, chassis
serial and part numbers, blade serial number, MAC address, and power
status for the active console.
Display platform
information
I
Powers the host subsystem on or off.
Power on/off host
subsystem
P
Resets the host subsystem with a hardware reset.
Important: F5
®
does not recommend using this option under typical
circumstances. It does not allow for graceful shutdown of the system.
Reset host subsystem
R
Runs the AOM network configuration utility. This utility enables you
to reconfigure the IP address, netmask, and default gateway used by
Configure AOM network
N
AOM. If you use this option while connected using SSH, your session
will be disconnected as a part of the network configuration operation.
Note: This option is not available when you are connected using SSH.
Sets a session idle timeout (in seconds) for the AOM SSH server.
Available values are 0 (no timeout; default value), or between 30 and
86400 (one day).
Configure SSH Server
S
Resets the AOM subsystem. In this case, the system is reset with a
hardware reset.
Important: We do not recommend using this option under normal
circumstances. It does not allow for graceful shutdown of the system.
Reset AOM
A
Buffers the last 4K bytes of console output from the host and saves it
to a non-volatile storage location.
Important: This option is hidden and disabled by default. It is intended
to be used as a diagnostic tool by F5 Support. When this option is
enabled, then disabled, the buffer is cleared.
Host Console Capture
Buffer
H
Displays a list of latched events/errors or out-of-range sensors.
Display error report
E
Exits the AOM Command Menu and returns to terminal emulation
mode.
Quit menu and return to
console
Q
Accessing the AOM Command Menu from the serial console
You can access the AOM Command Menu using the front panel serial console.
23
Platform Guide: 10000 Series
Summary of Contents for BIG-IP 10000 Series
Page 1: ...Platform Guide 10000 Series MAN 0408 08 ...
Page 2: ......
Page 6: ...6 Table of Contents ...
Page 44: ......
Page 48: ...Figure 13 Airflow in the 10000 Series platform 48 Environmental Guidelines ...
Page 58: ......
Page 60: ...7 Close and seal the shipping box 60 Repackaging Guidelines ...
Page 64: ......