69
Chapter 11
Echo Distance Module
On Forge Echo models, the Echo Distance is used in tandem
with the Transponder to measure distances and calculate limiting
diameters of trees from plot center on variable radius plots.
•
Tap
/ F4 Distance to open the program.
•
Remove the rubber cover at the top of the Forge.
•
Connect a 9 Volt battery to the Transponder.
•
While holding the Transponder to the Forge coupler, tap
Power and then F1-Open to open the transciever.
•
Next, tap F3-Power while still holding the Transponder to
the Forge coupler. Wait for the Transponder to power up. It
will chirp twice when it is powered up.
•
Tap F2-Close to close the set-up window.