Turn all Input Text’s OFF  

 

With alerts turned off the device will NOT text every time any Input changes but the Inputs are 
still active so you can send a “Input status” query at any time. Linked outputs will not work.  

 

Command: 

Alerts off

 

 

The system responds with:  

Alerts have been disabled  

(this is saved to memory and will still 

be disabled even after the unit is reset or rebooted) 
 

   OR 

 

Command: 

Alerts off exc links  

(

note

 only available in ver 1.2 or higher)

 

 

The system responds with:  

Alerts have been disabled but linked outputs will still work   

If an input is triggered no alert text will be sent but if the input has a link to an output that 
output will activate. 
 

 

Turn all Input Text’s ON  

 

Command: 

Alerts on

 

 

The system responds with:   

Alerts have been 

 

 
 
Testing  

 

Command: 

test     (only run this if you are present and can trigger the inputs)

 

 

The system responds with:   Battery is currently ??.?  volts, signal strength is ?? % , run test 
now. The unit will now test the inputs and outputs and waits for the inputs to be triggered.  
 
When input1 is turned on output1 will turn on, when input1 is turned off output1 will turn off 
When input2 is turned on output2 will turn on, when input2 is turned off output2 will turn off 
When input3 is turned on output3 will turn on, when input3 is turned off output3 will turn off 
When input4 is turned on output4 will turn on, when input4 is turned off output4 will turn off 
Test finished 

 

If the input or inputs are not triggered this command will time out after 1 minute. 

 

 

Get a list of the Inputs 

 

Command: 

Input status 

 

 

Currently, 

INPUT NAME

  is ??,  

INPUT NAME

  is ??  

 

Where ?? is either On or Off 

 

If an Input is a latching input and on: 

 

          

Currently the latching Input  

INPUT NAME

  

is on and latched   

 

If an Input is a latching input and off: 

 

          

Currently the latching Input  

INPUT NAME

  

is of

 

 
Get a list of the Outputs 

 

Command: 

Output status

 

 

The system responds with: 
 
 

Currently, 

Output Name  

 is ??, 

Output Name  

 is ?? 

 

Where ?? is either On of Off 

Ezy Switch SMS-IRR-4 Installation & Operation 

Summary of Contents for SMS-IRR-4

Page 1: ...EZY SWITCH LIMITED SMS IRR 4 System Monitor Installation Manual ...

Page 2: ...g the Input reply message 14 Turn an Output ON or OFF 15 Turn an Output ON for a set time 15 Invert Output 15 Make an Output Pulse On and Off 16 Clear Output Pulse Set to non pulsed 16 Make output public 17 Turn Output response On Off 17 Save Output Status 17 Linking Outputs 17 Set Battery Alarm trigger voltage 18 Link Battery Alarm to Output 18 Check Battery Supply Voltage 18 Latching Non latchin...

Page 3: ... Programmable Input delays max 99 minutes o Programmable for Latching or Non Latching Inputs o Programmable for Normally Open or Normally Closed Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Example Link intruder sensor or smoke detector input to light or alarm horn...

Page 4: ...a Retention Outputs Max Input voltage 12 to 30 Volts DC 800mA 40 Milli amps 10 years without power Relay 3 A resistive 125VAC 30vdc SMS IRR 4 Terminal Electrical Connections Terminal 1 Batt Terminal 2 Batt Terminal 3 Temperature sensor Terminal 7 Output 1 Terminal 4 Temperature sensor Terminal 8 Output 1 Terminal 5 Input 1 Terminal 9 Output 2 Terminal 6 Input 1 Terminal 10 Output 2 Terminal 11 Inp...

Page 5: ...tion Important Note A registered electrician must be used when connecting to the 120 240v main supply voltage Relay 2 Connection Internal Relay Relay Terminals 9 10 Relay 1 Connection Internal Relay Relay Terminals 7 8 Relay 3 Connection Internal Relay Relay Terminals 15 16 Relay 4 Connection Internal Relay Relay Terminals 17 18 ...

Page 6: ...llation Operation Temperature sensor Sensor Terminal 3 4 Fig 1a Switch 10 30vdc Input 1 Terminal 6 Or Input 2 Terminal 12 Or Input 3 Terminal 14 Fig 1b Fig 2 Switch Input2 Terminal 3 Temperature sensor Terminal 4 Terminal 5 Terminal 6 Switch Input4 Terminal 11 Switch Input3 Terminal 12 Terminal 13 Terminal 14 ...

Page 7: ...number without the preceding 0 If the users number is 0414884900 then Command add user 65414884900 USA Canada 001 1 and the Area Code Number If the users number is 414 555 1434 then Command add user 14145551434 IMPORTANT Ezy Switch SMS IRR 4 Installation Operation NOTE If a user sends a text message to the system which is not an exact match with the commands the system responds with Sorry either t...

Page 8: ...er number XXXXXXXX has been added to the user list Removing a User Command Remove user XXXXXXXX see Country Code page 7 If you try to remove the only user the system responds with Cannot delete the only user If the number sent is not currently on the list the system responds with XXXXXXXX is not currently in the user list so cannot be removed please check the number and try again If everything is ...

Page 9: ...unit using the Add User command as per above If User lookup is Off the SMS TEM 4 will respond to any number that sends the correct command The system responds with The user lookup list feature has been turned on and the unit will only accept commands from programmed users OR The user lookup list feature has been turned off and the unit will only accept commands from any numbers PLEASE NOTE Input c...

Page 10: ...lts signal strength is run test now The unit will now test the inputs and outputs and waits for the inputs to be triggered When input1 is turned on output1 will turn on when input1 is turned off output1 will turn off When input2 is turned on output2 will turn on when input2 is turned off output2 will turn off When input3 is turned on output3 will turn on when input3 is turned off output3 will turn...

Page 11: ...rename is not currently in the list the system responds with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chosen does not fulfill the requirements of a name the system responds with Sorry that name is not allowed please check that it is between 1 and 20 characters long If everything is ok the system responds...

Page 12: ...e Make alarm non latching This sets the Input to a NON latched Input and the system responds with The Input INPUT NAME is now a nonlatching input Reset a latched Input used to return Input to non activated state Command Reset INPUT NAME Example Reset alarm The system responds with INPUT NAME is no longer in a latched state and will begin to be monitored again If the Input is not latched the system...

Page 13: ...e The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 5 minutes until the text command Tick INPUT NAME off is sent max number of texts 20 To turn the feature on Command Make INPUT NAME tickoff on If everything is fine the system responds with The input tickoff feature has been turned on To turn the feature off Command Make...

Page 14: ...se the gate after using The Command for Input1 is Message3 please close the gate after using The Command for Input2 is Message4 please close the gate after using If everything is fine the system responds with The reply message has been set to please close the gate after using To turn the feature off and set back to factory settings simply send The Command for Input1 is Message1 The Command for Inp...

Page 15: ...an also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the system responds with The OUTPUT NAME on time has been set to XX mins or hrs or days If no value is set the system will respond with The OUTPUT NAME has been turned on and will stay on because no tim...

Page 16: ...t been set as per above the defalt time is 3 seconds and the system responds with OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds If the Output was initially On when the Output was set the system responds with OUTPUT NAME is now a pulsing output and has been turned off in preparation for use If the Output is linked to an Input when the Input is triggered the system sends ...

Page 17: ...n disabled response text will not be sent Save Output Status This command is used to define if the output state is saved to memory and restored to it state after a power recycle E g if an output was On when the power was turned off then when the power is restored the output will turn back on Note this does not apply if an output was turned on for a specified time System default is not saved Comman...

Page 18: ...d the alarm has been reset If the value XX X is outside the settings the system responds with Because the value is out of range the voltage alarm has been set to 11 5 volts and the alarm has been reset Link the Battery Alarm to an Output Command Link battery alarm to OUTPUT NAME The system responds with The battery alarm has successfully been linked to OUTPUT NAME and the alarm has been reset To c...

Page 19: ...ponds with The battery alarm has been cleared and will begin to be monitored again the linked output has also been turned off If the alarm is not currently set the system responds with The battery alarm is not currently active and does not need to be cleared Alive text feature only available in ver 1 2 or later This unit has an alive text feature which will send out a alive text as often as it has...

Page 20: ...this for all users that require the alive text If everything is fine the system responds with The number has been added to the alive text list Get Firmware Version Command Ver The system responds with SMS IRR 4 Ver X X Get Signal Strenth Command Sig The system responds with Currently the signal strength is XX Resetting the Unit Command Reboot The system responds with Module is now resetting Reset ...

Page 21: ...ending on the above Set alarm reset temperatures Both low and high alarm temperatures will be automatically reset approx 3 degrees above or below the temperatures depending on if the alarm is low or high OR the reset levels can be programmed Command Set temp yyy reset to xxx degrees where yyy is either high or low xx is the temperature Note is a minus temperature is required place the symbol befor...

Page 22: ...the time in minutes e g Set low temp on delay to 5 mins The system responds with The low alarm delay on time has been set to 5 mins Linking alarms to outputs Both low and high alarm can be linked to an output Command Link xxxx alarm to OUTPUT NAME xxxx can be the word low or high OUTPUT NAME the name of the output The system responds with The temperature xxxx alarm has been linked to OUTPUT NAME w...

Page 23: ...ll turn the feature Off The system responds with The Irrigator feature has been turned can be on or off Irrigator2 Feature For applications where a pump or irrigator connected to output1 is turned on via a text and turned off either by a text or if input 2 turns off when input 2 is connected to a flow switch When the pump turns on then input2 should also turn on due to water flow if input2 does no...

Page 24: ...s with example 41 1019148 S 174 8678127 E has been set as the home location If the unit moves outside of the home location the following text will be sent ALARM the unit has moved outside the home location If the unit moves back inside the home location the following text will be sent The unit has moved back inside the home location To turn this feature off Command gps alarm off The system respond...

Page 25: ...PUT NAME to GPS The system responds with INPUT NAME has been linked to the GPS alarm To turn this feature off Command Clear gps link The system responds with The GPS linked alarm has been removed Setting Geo Fence Command Set lat xx The system responds with Lat variation has been set to xx Command Set long xx The system responds with Long variation has been set to xx System defaults are Lat 35 Lon...

Page 26: ...e replaced product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agents accept any liability for any direct indirect or consequential losses or damages whatsoever or howsoever arising from the use of the product Where conditions or warranties are implied or other rig...

Page 27: ... message Input Name has been turned on If the input turns back off before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it will also state the linked output has also been turned on Off Delay This delay is used when the input turns OFF Example If input1 has an OFF delay of 10mins when Input1 turns OFF the unit will wait 10 ...

Page 28: ...p in degrees area Low alarm temp in degrees area Low Alarm The unit will alarm if the current temperature is equal to or less than the programmed low set point temperature e g set point 15 degrees alarm point will be equal or less than 15 degrees e g set point 15 degrees alarm point will be equal or greater than 15 degrees 15 10 0 0 10 Alarm set point 25 20 15 Alarm area 80 20 Alarm set point Alar...

Page 29: ... different location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM network hence the slow flashes but the signal strength is to low 1 Replace aerial with high gain aerial 2 Move unit to different location 3 SIM card NOT registered with the network provider 4 No credit on...

Page 30: ...30 All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 1 1 ...

Reviews: