9
9
Plug the female fitting into the receptacle on the rear of the pump side frame. Depress and hold the “Boom
Out” button.
Both of the unit arms will begin to move up and back towards the
rear of the truck bed. It is normal
that the arm on the pump side should move at a brisker pace than
the other side. Bring the arms all of the way out to the rear. The
unit is bled at the factory.
Note. It is important to watch the
fluid level in the pump reservoir for the entire movement of the
arms. If the fluid level drops too low during the arm move-
ment it will be necessary to bleed the system.
As the arms come out, the hydraulic fluid level in the pump reservoir will
drop towards the bottom indentation in the reservoir (indicated by the red
line in the illustration). Allowing the fluid level to drop below the bottom
indentation may lead to air entering the system. As the level approaches the
bottom indentation release the “Boom Out” button to stop the arms. Use
the hydraulic fluid provided to refill the reservoir up to the level of the top
reservoir indentation indicated by the black line in the illustration.
After the Boom has been extended completely out, depress and hold the
“Boom In” button on the remote to bring the arms to the full in position.
MOUNT THE WINCH CROSSBAR
Use the remote control to bring the arms out to about chest
high when standing in the bed. The arm on the pump side
will rise much faster than the arm on the opposite side.
When the pump side arm reaches the correct height simply
hold it down until the opposite side arm reaches a parallel
height then release the “boom out” button on the remote.
Summary of Contents for 2000
Page 1: ......
Page 19: ...19 19 Hydraulic Diagram ...
Page 20: ...20 20 Electrical Diagram ...
Page 21: ...21 21 ...