background image

5. 

Check mounting bolts of actuator

 top and bottom. Pay particular attention to top bolt hole for elongation. 

 

 

Check actuator for the following.

 Inspect the plastic housing for any dents or cracks. 

☐ 

Inspect the cables to see if they have been cut or pinched.

☐ 

See if the actuator appears deflected when fully extended under load.

☐ 

Verify that the mounting points do not have any cracks or other defects. 

☐ 

Apply a heavy grease to actuator mounting pins as needed.   

 

 

☐ 

Verify that the inner or outer tubes do not have any dents, dings, or large scratches in them.

Contact EZ Way’s Service Department if the actuator shows any signs of  
the issues listed above.

TOP OF
ACTUATOR

ELONGATED

BOTTOM OF
ACTUATOR

At six month intervals, attach a load equivalent to or within 100 lbs of the rated capacity of the 

stand to the unit

. Do not exceed the rate weight capacity. Raise and lower the load with the lift. Listen for 

any unusual noises while operating the unit. With the test load applied to the lift, check all structural welds 

for any signs of stress or fatigue cracks. If any unusual noises or cracks are found, stop using the stand and 

call the EZ Way Service Department immediately!  

 

Test the Emergency Stop Switch

. If the switch does not stop the stand when activated, call the EZ Way  

Service Department immediately!

Perform a functional test of the emergency lowering feature

 of the stand actuator if it is so equipped.

Perform a functional test of the anti-pinch feature

 of the stand actuator. This feature turns the  

actuator off when lowering the stand arm if an obstruction is encountered.

Check all the wheels and brakes

 to make sure they are functioning properly. Hair that gets picked up 

and wrapped in between wheels should be cleaned out so that the stand will roll easily.

Do a visual check

 for any damaged, missing or loose parts. Repair as necessary.

Check the entire harness for damage or wear

, including the loops and stitching.  If damage or wear is  

present, discard the harness and order a new one. It is recommended that harness be replaced after one year 

or if the sling shows any sign of damage or wear.

When cleaning the stand, do not spray any liquid cleaners directly onto the front panel graphics

.  

To clean, use a glass cleaner such as Windex, dampen a cloth and wipe the panel.

IMPORTANT NOTICE 

It is the responsibility of the purchaser to ensure  
that regular maintenance inspection is conducted  
on this device by competent staff.

6

8

9

7

10

11

12

13

14

DATE COMPLETED:
COMPLETED BY:
PASS / FAIL:
MODEL & SERIAL NO.:
EQUIPMENT PURCHASE DATE:

Summary of Contents for Smart Stand S400

Page 1: ...Service Manual Model S400 and S500 Smart Stand Form 1 145 Rev 02 05 19 WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 2: ...ax 712 542 1899 www ezlifts com Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 7 Smart Stand Operating Instructions 9 Scale Calibration 10 Advanced Smart Stand Features 11 Wiring Sc...

Page 3: ...Non Scale Parts Diagram EZ Way Inc 800 627 8940 Fax 712 542 1899 www ezlifts com Page 3 S400 S500 Non Scale Parts List 400 EZ Smart Stand without Scale Model S400PN Part List 500 EZ Smart Stand witho...

Page 4: ...ok Spring 17 50932 Pad Head Stand 400 lb 18 12013 Actuator Assembly Stand 19 12706 Hand Control Assembly 20 13506 Linkage Rod Assembly Lift Stand 500 EZ Smart Stand w out Scale Model S500PN Item Part...

Page 5: ...With Scale Parts Diagram EZ Way Inc 800 627 8940 Fax 712 542 1899 www ezlifts com Page 5 S400 S500 With Scale Parts List 400 EZ Stand with Scale Premier Model 8992 Part List 500 EZ Stand with Scale Pr...

Page 6: ...Stand 400 lb 20 12013 Actuator Assembly Stand 21 12706 Hand Control Assembly 22 13506 Linkage Rod Assembly Lift Stand 500 EZ Smart Stand with Scale Model S500PS Item Part No Description 1 11842 Switch...

Page 7: ...not missing or torn PIN ON FOOT PLATFORM ARM TO MAST BASE PIVOT REAR WHEEL FRONT WHEEL LINKAGE SPREADER EZ Way Smart Stand Safety Maintenance Checklist EZ Way Inc The EZ Way Smart Stand requires a mi...

Page 8: ...Test the Emergency Stop Switch If the switch does not stop the stand when activated call the EZ Way Service Department immediately Perform a functional test of the emergency lowering feature of the s...

Page 9: ...a symbol indicating that the weight is recalled MENUS Enter Customer Settings Menu Weight Calibration 1 After power up sequence press and hold the Down key followed quickly by the Up key and hold bot...

Page 10: ...to ensure the scale is functional 5 Enter the calibration menu After power up sequence press and hold the DOWN key followed quickly by the UP key and hold both keys for 5 seconds 6 Press the UP key to...

Page 11: ...ustomer will need to wait 15 minutes to cool the actuator motor Actuator Overload For Arm Protection 1 When an Up or Down command is executed the circuit board monitors current consumed by the actuato...

Page 12: ...me since the last inspection exceeds 30 days a reminder message will appear when the unit is powered up The purpose of the inspection reminder is to notify the customer that the lift or stand needs to...

Page 13: ...s read only information provides customer feedback for accidental lifting of a trapped harness accidental lifting of arm against obstruction or accidental lifting of overweight patient Lift Stand Tota...

Page 14: ...EZ Way Inc EZ Way Inc 800 627 8940 Fax 712 542 1899 www ezlifts com 14 Smart Stand Wiring Schematic...

Page 15: ...ake sure on off button is not flattened out Check if green LED is flashing on board Flashing LED indicates the PCB is getting power Make sure W6 jumper is in place No up down but display works Check c...

Reviews: