Notice: The connection by network is not as fast as the connection by RS232.
If you want to change the network settings of omniSHAPES, connect your PC to the
omniSHAPES by serial Port. Then choose the omniSHAPE on which you want to adjust the
IP-address, Gateway or Subnet Mask and set it to the values you want by pressing the
button
Set to Device
.
7.3.2. Serial connection Settings
Press the button
Preferences
for the connection settings
.
You have to do some settings before.
1. Choose the com-Port
2. Choose the baud-rate 115200 baud or 256000 baud.
3.
Choose “8N1”
4.
Press “Open Serial Port”
Choose on omniSHAPE or the complete wall, after it’s chosen, the color switches from grey to
light purple.
Press
Connect
to get connected to the omniSHAPE.
After the omniSHAPE Designer is connected the omniSHAPE the color has changed to dark
purple.