Eyecon 9420 & 9430 Instruction Manual
51
3.6 Pharm. Mgmt. SW menu
3.6.9 Photo Retriever Application:
Tap
Photo Retriever Application:
to see the screen
at right. You can choose to enable the photo
retriever application so an external computer can
request individual annotated tray photos from the
Eyecon. Check with your pharmacy software
provider to determine if they support viewing of the
counting platter photos from within their
application.
3.6.10 Photo Retriever Port:
Tap
Photo Retriever Port:
to bring up the numeric keypad. Key in the port number that
the Eyecon will be listening to for retrieval of the counting platter photos. The default
port is 80 as most PMSS providers that support this feature also use port 80.
3.6.11 Allow Rx Refills
This parameter allows the Eyecon to refill an Rx that has previously been recorded as
filled. If set to, “
Disabled
,” the Eyecon will not allow the process to continue when the
Rx has been previously filled.
3.6.12 Provide Prior Fill Warning
For pharmacies that use the same Order ID value for every fill and that have enabled
Allow Rx Refills, enabling this parameter prevents the refill warning from being shown.
3.6.13 Echo Received PMSS Packets
This feature allows the Eyecon to echo an incoming Rx fill request sent by the PMSS
system to up to 3 other devices on the pharmacy network. This is useful if the PMSS
system cannot send Rx Fill requests to multiple devices. In this case, the PMSS system
can send the Rx fill request to an Eyecon on the network. The Eyecon then echoes the
request to other devices on the network that are visible to the Eyecon. Enabling this
parameter results in the next four ‘Echo’ parameters becoming visible in the
Data
Menu
.
3.6.14 Echo Port #
Select
Echo Port #
to define the port number for the IP addresses defined in the
following parameters. The device the Eyecon is echoing the request to must be ready
to receive the incoming packet on this port #.
This completes the
Pharm. Mgmt. SW
menu.