![extronics iCAM50 Operating Manual Download Page 5](http://html1.mh-extra.com/html/extronics/icam50/icam50_operating-manual_2457385005.webp)
Operating Manual
5
1 Safety Information and Notes
1.1 Storage of this Manual
Keep this user manual safe and in the vicinity of the device. All persons required to work with
the device should be advised on where this manual is stored.
Important
This manual applies to both the iCAM501U and iCAM502. It is important
to note the different safety instructions for these two products. When
‘iCAM50x’ is used in this manual, it applies to both the iCAM501U and
iCAM502.
1.2 Special Conditions For Safe Use
1.2.1 ATEX / IECEx
1.2.1.1 iCAM501U
(Taken from ITS09ATEX2868X Issue 3 Section 17 and IECExITS09.0027X Issue 2)
For Group II applications only, the user shall not carry more than a maximum of two spare
MN 1500 AA cells into the hazardous area. Precautions shall be taken to prevent short
circuiting of un-protected battery terminals. Discharged cells shall be removed from the
hazardous area.
For Group 1 applications, the changing of the batteries in the hazardous area and the
transportation of spare batteries into the hazardous area is not permitted.
The USB port shall only be connected in the non-hazardous area
If the camera is damaged in any way, it shall be removed from the hazardous area.
1.2.1.2 iCAM502
(Taken from ITS09ATEX2868X Issue 4 (Amended March 2013) Section 17 and IECExITS09.0027X
Issue 4)
For Group II applications only, the user shall not carry more than a maximum of two spare
approved AA cells into the hazardous area. Precautions shall be taken to prevent short
circuiting of un-protected battery terminals. Discharged cells shall be removed from the
hazardous area.
The Temperature class for the equipment is determined by type of batteries used.
T4: Duracell MN 1500
T3: Duracell Procell PC 1500, Energizer E91, Panasonic LR6XWA
For Group 1 applications, the changing of the batteries in the hazardous area and the
transportation of spare batteries into the hazardous area is not permitted.
Duracell MN 1500 is the only type of battery permitted for Group 1 applications
The USB port shall only be connected in the non-hazardous area
If the camera is damaged in any way, it shall be removed from the hazardous area.
Summary of Contents for iCAM50
Page 4: ...Operating Manual 4...
Page 36: ...Operating Manual 36 6 Certification 6 1 iCAM501U EC Declaration of Conformity...
Page 37: ...Operating Manual 37 6 2 iCAM502 EC Declaration of Conformity...
Page 38: ...Operating Manual 38 6 3 iCAM501U Class 1 Division 1 Certificate of Compliance...
Page 39: ...Operating Manual 39...
Page 40: ...Operating Manual 40...
Page 41: ...Operating Manual 41...