background image

Operating Manual         

 

 

Warning          Do not exceed the Effective Isotropic Radiated Power (EIRP) for the gas 

group  in  which  the  iANT2xx  will  be  operating.  The  RF  output  of  the 
transceiver will vary depending on the hardware and antenna used. The 
maximum hardware limit of the access point must be used to calculate 
the EIRP 

 software control by the user of the RF power is not allowed 

 
                         - Group IIC 

 2W (+33dBm) 

                         - Group IIB 

 3.5W (+35.4dBm) 

                         - Group IIA/I/III 

 6W (+37.7dBm) 

 
                      Refer to Table 1 for specific antenna details. 
 
 
Important 

iANT2xx are only certified for use in ambient temperatures in the ranges 
specified in Table 1 and should not be used outside this range. 

 

 

 

Important      Do not exceed the Effective Isotropic Radiated Power (EIRP) limit for the 
                      country / region of operation 
 
Important 

Repair of the iANT2xx shall only be carried out by the manufacturer. The 
antennas contain no user-serviceable parts. 

 

Summary of Contents for iANT2 Series

Page 1: ...Operating Manual iANT2xx Series of Antennas...

Page 2: ...is intentionally left blank Document Number 403449 4 2021 Extronics Limited This document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without noti...

Page 3: ...ion and Storage 8 2 5 Authorized Persons 8 2 6 Cleaning and Maintenance 8 2 7 Safety Precautions 9 2 8 Cleaning and Maintenance Intervals 9 2 9 Aggressive substances and environments 9 2 10 Exposure t...

Page 4: ...us equipment used in an intrinsically safe electrical system is compliant with IEC 60079 0 IEC 60079 11 IEC 60079 14 IEC 60079 25 Extronics has assessed the iANT2xx antenna range together with our int...

Page 5: ...nic isolator Do not use an iANT2xx antenna without first contacting Extronics for guidance and recommendations for the use of the iANT2xx with specific hardware Important Installation of this equipmen...

Page 6: ...user of the RF power is not allowed Group IIC 2W 33dBm Group IIB 3 5W 35 4dBm Group IIA I III 6W 37 7dBm Refer to Table 1 for specific antenna details Important iANT2xx are only certified for use in...

Page 7: ...8 24 5 0 49 26 9 0 85 29 3 0 85 29 3 Y iANT214 2400D 2 4GHz 8 Sector 40 C to 80 C 0 32 25 0 55 27 4 0 95 29 8 0 95 29 8 Y iANT214 5000 5 8GHz 14 Sector 40 C to 80 C 0 08 19 0 14 21 4 0 24 23 8 0 24 23...

Page 8: ...risk in such cases 2 4 Transportation and Storage All iANT2xx series devices must be so transported and stored that they are not subjected to any excessive mechanical stresses 2 5 Authorized Persons O...

Page 9: ...and Maintenance Intervals The cleaning intervals depend on the environment where the system is installed 2 9 Aggressive substances and environments The iANT2xx series is not designed to come into cont...

Page 10: ...nting Details 3 1 iANT212 The iANT212 is designed to be mounted directly to wireless devices therefore no mounting bracket is supplied with this antenna 3 2 iANT213 The IANT213 is supplied with a pole...

Page 11: ...Operating Manual 11 3 3 iANT214...

Page 12: ...Operating Manual 12 3 4 iANT215 3 5 iANT216 The iANT216M is designed to be mounted directly to wireless devices The iANT216F is supplied with a pole mount bracket as standard...

Page 13: ...3 6 iANT217 Mounting bracket is available The iANT217 is suitable for wall or pole mounting Pole mount bracket Extronics part number iANTMB217 Note this bracket is aluminium and is not suitable Group...

Page 14: ...m No 5 as illustrated with items 6 7 8 13 Teeth of item 5 facing teeth of item 3 Leave screw slightly loose 6 For pole mounting attach items No 4 and 5 to the pole as illustrated Fig 4 and connect tho...

Page 15: ...Operating Manual 15 3 7 iANT227 The antenna mounts directly to connector on the unit itself or it may also be pipe mounted and fed with an RF connector when alternative positioning is required...

Reviews: