Operating Manual
9
2.7
Safety Precautions
Important
For the installation, maintenance and cleaning of the units, it is absolutely
necessary to observe the applicable regulations and provisions
concerned with explosion protection (IEC 60079-0, IEC 60079-14) as well
as the Accident Prevention Regulations.
Warning
The maximum radiated power must not exceed that allowed in the area of
installation (IEC 60079-0). IIC -2W, IIB
–
3.5W, IIA
–
6W
2.8
Cleaning and Maintenance Intervals
The cleaning intervals depend on the environment where the system is installed.
2.9
Aggressive substances and environments
The iANT2xx series is not designed to come into contact with aggressive substances
or environments, please be aware that additional protection may be required.
2.10
Exposure to external stresses
The iANT2xx series is not designed to be subjected to excessive stresses e.g.
vibration, heat, impact. Additional protection is required to protect against these
external stresses.
The iANT2xx series will require additional protection if it is installed in a location
where it may be subjected to damage.