Extron electronics TLP Pro x25M Series Setup Manual Download Page 5

 

5

Product Category

A

 

MENU Button

 (see 

figure 4

 on the previous page)— Activates the setup menu (see 

Setup Menu

 on the next page).

B

 

RESET Button 

— Pressing the 

Reset

 button allows the unit to be reset in any of three different modes (for an overview, see 

Reset Modes

, on the next page).

C

 

RESET LED 

— Provides feedback about the reset status when the user presses the 

Reset

 button (see 

Reset Modes

).

D

 

Mounting Slots

 — The TLP Pro 725M and TLP Pro 1025M have four, one in each corner. The TLP Pro 525M has two, one in each 

top corner. The hooks on the corners of the mounting plate (see 

figure 1

3

 on page 2) fit into these slots for wall mounting.

E

 

Digital Input Monitoring Port

 — This two-pole captive screw port (

1

 = signal and 

G

 = ground) monitors digital input with or 

without a +5 VDC pull-up. 

F

 

LAN/PoE Connector

 — Connect the TouchLink panel to a PoE power injector (not provided) using a twisted pair cable, 

terminated with an RJ-45 connector. Connect the power injector to the LAN through a nework switch. An Extron IP Link Pro 
control processor must also be connected to the same network as the TouchLink Pro touchpanel. TLS models do not require a 
control processor

ATTENTION:

• 

The TouchLink panels are Power over Ethernet (PoE 802.3af, class 3) compliant. Do not power on the touchpanels 
until you have read the Attention in the “Rear Panel Features” section of the 

TLP Pro 525, 725, and 1025 Series 

User Guide

.

• 

Les écrans TouchLink supportent l’alimentation via Ethernet (PoE 802.3af, classe 3). Veuillez lire la partie 
« Attention » dans la section « Rear Panel Features » du 

TLP Pro 525, 725, and 1025 Series User Guide

, avant de 

mettre sous tension les écrans tactiles.

NOTE:

  These TouchLink panels are shipped without a power 

injector. The power injector must be purchased separately.

Menu Button

Reset Button

Reset LED

Mounting Slots

Digital Input Monitoring Port

LAN/PoE Connector

Extron recommends the Extron XTP PI 100 power injector (see figure 5). 
Your power injector may look different.

G

 

USB Port

 — Compatible with USB 2.0. 

H

 

Speaker

 — Provides audible feedback for the user.

• 

TLP Pro 525M and TLS 525M

 — a single speaker

• 

TLP Pro 725M and TLS 725M

 — a single speaker

• 

TLP Pro 1025M and TLS 1025M

 — two (dual mono) speakers

USB Port
Speaker

100-240V 

~

 50-60Hz

0.4A MAX

XTP

PWR

XTP PWR

To network switch

To TouchLink panel

Figure 5. 

XTP PI 100 Power Injector

figure 5

I

 

Slot for Mounting Plate

 — The tongue at the bottom of the mounting plate (see 

figure 1

4

) fits into this slot, for wall mounting.

J

 

Mounting Screw

 — Tightens against the tongue of the mounting plate to secure the TouchLink panel.

K

 

Rear Panel Status Lights

 — These lights can be disabled for glass mount applications.

• 

TLP Pro 525M and TLS 525M

 — no lights

• 

TLP Pro 725M and TLS 725M

 — Six lights, three on each side of the panel

• 

TLP Pro 1025M and TLS 1025M

 — Two lights, one on each side of the panel

TLS models

 — The LEDs light green when the room is currently available and red when the room is currently booked. They 

cannot be programmed.

TLP Pro models

 — The LEDs can be configured to light red or green and to blink or light continuously, to provide system 

feedback. 
The rear panel status lights can be toggled between enabled and disabled by using the 

Setup Menu

 (see the next page).

For information about programming these LEDs for the TLP Pro x25M models, see the 

Global Configurator Help File

 and 

Global 

Scripter Help File

.

Mounting Screw

Slot for Mounting Plate

Rear Panel Status Lights

Summary of Contents for TLP Pro x25M Series

Page 1: ...mming TLS scheduling panels Room Agent Free room booking software for configuring the panels for room scheduling NOTE All five software programs and supporting documentation are available from www extron com Obtain the following network information from your network administrator DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either a...

Page 2: ...n box Junction boxes or wall boxes must be purchased separately Figure 1 shows the TLP Pro 725M Installation for the other panels is very similar NOTES The 5 inch models mount to a 1 gang junction box The US 1 gang junction box should be installed so that the long side is horizontal EU or MK 1 gang junction boxes should be installed in the standard orientation The 7 and 10 inch models mount to a 2...

Page 3: ... 3 shows the front panel of the TLP Pro 725M The front panels of all the TouchLink panels have the same features and are almost identical apart from the size A Motion sensor Detects motion between three to five feet from the TouchLink panel and at least 15 from the center axis If the sleep timer has been set see Setup Menu on page 6 and no motion has been detected for a user defined period of time...

Page 4: ...ear panel features as the corresponding TLP Pro models For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mounting Screw K Rear Panel Status Lights E Status lights Two LED light bars one on either side of the screen see figure 3 on the...

Page 5: ... la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These TouchLink panels are shipped without a power injector The power injector must be purchased separately n n s t Extron recommends the Extron XTP PI 100 power injector see figure 5 Your power injector may look different G USB Port Compatible with USB 2 0 H Speaker ...

Page 6: ...ry default settings NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensitive If the device is reset to default settings the password will be the default password configuration The default password is extron for either admin or user Enable or Disable the DHCP Client This mode toggles between DHCP enabled and DHCP d...

Reviews: