Figure 2. 

Mounting Plates for 5 inch models (left) and 7 or 10 inch models (right)

NOTE: 

The TLP Pro 725M, TLS 725M, TLP Pro 1025M, and TLS 1025M TouchLink panels use the same mounting plate.

Without a wall box

If the wall box is not required by local building codes, you can mount the TouchLink panel directly into drywall. 

1. 

Use the mounting plate as a template to mark the wall or download the cut-out template for your product from 

www.extron.com

Place the template or mounting plate against the wall or furniture in a suitable location and ensure that it is level. 

2. 

Mark the position of the hole and cut the wall.

• 

For the 5 inch models, this hole is 2.4 inches (61 mm) wide x 2.1 inches (53 mm) high.

• 

For the 7 or 10 inch models, this hole is 3.5 inches (89 mm) wide x 2.0 inches (51 mm) high.

3. 

Mark the slots labeled 

WALL

 (5 inch models) or 

MK

 (7 or 10 inch models) (see figure 2) and drill the two pilot holes. Extron 

recommends using two Molly bolts or SnapToggle bolts.

4. 

Secure the mounting plate to the wall (see 

figure 1

2

, on the previous page).

5. 

Complete the installation as described in 

steps 3 through 6

 on the previous page.

figure 2

Front Panel Features

NOTE: 

Figure 3 shows the front panel of the TLP Pro 725M. 

The front panels of all the TouchLink panels have the same 
features and are almost identical apart from the size.

A

 

Motion sensor

 — Detects motion between three to five feet 

from the TouchLink panel, and at least 15° from the center 
axis.

• 

If the sleep timer has been set (see 

Setup Menu

 on 

page 6), and no motion has been detected for a 
user-defined period of time, the TouchLink panel enters 
sleep mode.

• 

If Wake on Motion has been set (see 

Setup Menu

), and 

motion is detected by the sensor while the screen is in 
sleep mode, the screen display is restored and active.

Extron

A

A

A B

B

B C

C

C A

A

A

D

D

D

E

E

E

E

E

E

Figure 3. 

TLP Pro 725M Front Panel

B

 

Communication LED

 — (

TLP Pro models only

) Shows the configuration and connection status of the touchpanel:

• 

Unlit during normal operation (the touchpanel is configured and connected to an IP Link Pro control processor).

• 

Blinks red if the touchpanel has been configured but is not connected to an IP Link Pro control processor.

• 

Lights steadily red if the touchpanel has not been configured.

The indicator can be toggled between enabled and disabled, using the 

Setup Menu

C

 

Light sensor

 — Monitors ambient light level and adjusts screen brightness.

D

 

Capacitive touchscreen

• 

The TLP Pro 525M series and TLS 525M have a 5 inch screen with a 800x480 resolution.

• 

The TLP Pro 725M series and TLS 725M have a 7 inch screen with a 1024x600 resolution.

• 

The TLP Pro 1025M series and TLS 1025M have a 10.1 inch screen with a 1280x800 resolution

figure 3

Summary of Contents for TLP Pro x25M Series

Page 1: ...mming TLS scheduling panels Room Agent Free room booking software for configuring the panels for room scheduling NOTE All five software programs and supporting documentation are available from www extron com Obtain the following network information from your network administrator DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either a...

Page 2: ...n box Junction boxes or wall boxes must be purchased separately Figure 1 shows the TLP Pro 725M Installation for the other panels is very similar NOTES The 5 inch models mount to a 1 gang junction box The US 1 gang junction box should be installed so that the long side is horizontal EU or MK 1 gang junction boxes should be installed in the standard orientation The 7 and 10 inch models mount to a 2...

Page 3: ... 3 shows the front panel of the TLP Pro 725M The front panels of all the TouchLink panels have the same features and are almost identical apart from the size A Motion sensor Detects motion between three to five feet from the TouchLink panel and at least 15 from the center axis If the sleep timer has been set see Setup Menu on page 6 and no motion has been detected for a user defined period of time...

Page 4: ...ear panel features as the corresponding TLP Pro models For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mounting Screw K Rear Panel Status Lights E Status lights Two LED light bars one on either side of the screen see figure 3 on the...

Page 5: ... la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These TouchLink panels are shipped without a power injector The power injector must be purchased separately n n s t Extron recommends the Extron XTP PI 100 power injector see figure 5 Your power injector may look different G USB Port Compatible with USB 2 0 H Speaker ...

Page 6: ...ry default settings NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensitive If the device is reset to default settings the password will be the default password configuration The default password is extron for either admin or user Enable or Disable the DHCP Client This mode toggles between DHCP enabled and DHCP d...

Reviews: