Reset Modes: a Brief Summary

These TouchLink panels provide the following reset modes (see the 

TLP Pro 525, 725, and 1025 Series User Guide

 for complete 

information):

• 

Use Factory Firmware 

— With the unit powered off, press and hold the 

RESET

 button (see 

figure 4

B

 on page 4

) while 

reapplying power to the unit. Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from 
uploading a firmware update.

• 

Reset All IP Settings 

— Press and hold the 

RESET

 button for 6 seconds. After the 

RESET

 LED (

C

) blinks twice, release and 

momentarily press the 

RESET

 button. Use this mode to reset all network settings without affecting user-loaded files.

• 

Reset to Factory Defaults 

— Press and hold the 

RESET

 button for 9 seconds. After the Reset LED blinks three times, release 

and momentarily press the 

RESET

 button. Use this mode to return the TouchLink panel to factory default settings.

NOTES:

• 

The factory configured passwords for all accounts on this device have been set to the device serial number. 
Passwords are case sensitive.

• 

If the device is reset to default settings, the password will be the default password configuration. The default 
password is 

extron

 (for either admin or user).

• 

Enable or Disable the DHCP Client

 — This mode toggles between DHCP enabled and DHCP disabled. Press the 

Reset

 

button five times, consecutively. After the fifth press, do not press the button again within 3 seconds. If DHCP was enabled, it 
is now disabled and the 

Power

 LED blinks three times. If DHCP was disabled, it is now enabled and the 

Power

 LED blinks six 

times.

Reset Modes

Status

Display

Audio

Advanced

Exit

Network

Info

Model:

TLP Pro 725M

Part Number: 60-1563-02
Firmware

Version:

1.02.0001-b001

Network

IP Address:
DHCP:
Host Name:

Off

192.168.254.251

TLP-AB-CD-EF

Display

Resolution:
GUI Project:
Sleep Timer:

1024x600
N/A
5 Minutes

Audio

System Volume:
System Mute:

Off

99

Advanced

Controller IP:

N/A

Project Size:

N/A

Bootloader

Version:

1.03.0000

Figure 6. 

Setup Menu: Status Screen for TLP Pro 725M

Setup Menu

Figure 6 shows the Status screen for the TLP Pro 725M. The 
screen for the TLP Pro 525M, TLP Pro 1025M, and the TLS 
models are similar.
Press the 

MENU

 button (

figure 4

A

) to open the setup menu. 

Select any of the five available screens (

Status

Network

Display

Audio

, and 

Advanced

) by pressing the appropriate 

button in the navigation bar at the top of the screen (for more 
information, see the 

TLP Pro 525, 725, and 1025 Series User 

Guide

).

68-2831-55 Rev. B

10 21

Summary of Contents for TLP Pro x25M Series

Page 1: ...mming TLS scheduling panels Room Agent Free room booking software for configuring the panels for room scheduling NOTE All five software programs and supporting documentation are available from www extron com Obtain the following network information from your network administrator DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either a...

Page 2: ...n box Junction boxes or wall boxes must be purchased separately Figure 1 shows the TLP Pro 725M Installation for the other panels is very similar NOTES The 5 inch models mount to a 1 gang junction box The US 1 gang junction box should be installed so that the long side is horizontal EU or MK 1 gang junction boxes should be installed in the standard orientation The 7 and 10 inch models mount to a 2...

Page 3: ... 3 shows the front panel of the TLP Pro 725M The front panels of all the TouchLink panels have the same features and are almost identical apart from the size A Motion sensor Detects motion between three to five feet from the TouchLink panel and at least 15 from the center axis If the sleep timer has been set see Setup Menu on page 6 and no motion has been detected for a user defined period of time...

Page 4: ...ear panel features as the corresponding TLP Pro models For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mounting Screw K Rear Panel Status Lights E Status lights Two LED light bars one on either side of the screen see figure 3 on the...

Page 5: ... la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These TouchLink panels are shipped without a power injector The power injector must be purchased separately n n s t Extron recommends the Extron XTP PI 100 power injector see figure 5 Your power injector may look different G USB Port Compatible with USB 2 0 H Speaker ...

Page 6: ...ry default settings NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensitive If the device is reset to default settings the password will be the default password configuration The default password is extron for either admin or user Enable or Disable the DHCP Client This mode toggles between DHCP enabled and DHCP d...

Reviews: