1
:
e
complete user guide and installation
instructions befor
product to the power sou
rce.
TLP Pro x25M and TLS x25M Series TouchLink Panels
Setup Guide
Overview
The Extron TLP Pro 525M, 725M, and 1025M are three series of wall mounted, capacitive touchscreen, TouchLink
®
panels with TFT
active matrix color LCD screens with 24-bit color depth.
The TLS 525M, 725M, and 1025M have identical features but use the Room Agent software to coordinate room scheduling.
•
The
TLP Pro 525M
and
TLS 525M
models have a 5 inch screen with a 800x480 resolution.
•
The
TLP Pro 725M
and
TLS 725M
models have a 7 inch screen with a 1024x600 resolution.
•
The
TLP Pro 1025M
and
TLS 1025M
models have a 10.1 inch screen with a 1280x800 resolution.
This guide provides instructions for experienced installers to mount and install these TouchLink panels.
Setup Checklist
Get Ready
Download and install the latest version of the following software onto the PC being used to configure the TouchLink panel:
Toolbelt
— Provides device discovery, device information, firmware updates, and configuration of network settings, system
utilities, and user management for TouchLink Pro devices and scheduling panels.
TLP Pro touchpanels
GUI Designer
— For designing layouts for Extron TouchLink Pro touchpanels and third party touch interfaces.
Global Configurator
®
Professional and Global Configurator Plus
— For setting up and configuring the control processor
and TouchLink panel.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
TLS scheduling panels
Room Agent™
— Free room booking software for configuring the panels for room scheduling.
NOTE:
All five software programs and supporting documentation are available from
.
Obtain the following network information from your network administrator:
DHCP status
— (on or off). If DHCP is off, you must also obtain:
IP address
Subnet mask
Gateway
User name
— This can be either
admin
or
user
.
Password
— The factory configured passwords for all accounts on this device have been set to the device serial number.
Passwords can be changed during configuration. Passwords are case sensitive.
NOTE:
If the device is reset to default settings, the password is the default password configuration. The default
password is
extron
(for either admin or user).
Make a note of the TouchLink panel MAC address, which can be found on a rear-panel label.
Mount and Cable All Devices
ATTENTION:
•
Do not power on the TouchLink panels until you have read the Attention in the “Rear Panel Features” section of the
TLP Pro 525, 725, and 1025 Series User Guide
.
•
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section « Rear Panel Features » du
TLP Pro 525, 725, and 1025 Series User Guide
.
Mount the units. There are several mounting options for TouchLink panels (see
on the next page).
Connect the TouchLink panel to a Power over Ethernet injector (see
Connect the power injector to the LAN and power it on (
).
Set up the TouchLink Panels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel
to the same Ethernet subnetwork
.
Use the
(see page 6) or Toolbelt to set the DHCP status and, if required, network addresses for the TouchLink
panel.