Mounting
This section outlines the various options for:
•
Rack Mounting the TLP 1000MV
•
Wall Mounting the TLP 1000MV
•
Surface Mounting the TLP 1000MV
•
Wall Mounting the TLP 1000MV with a Wallbox
•
Desktop Mounting the TLP 1000TV
•
Removing the TLP 1000TV base for VESA Mounting
•
VESA mounting the TLP 1000TV
Rack Mounting the TLP 1000MV
Underwriters Laboratories Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation
of these products in a rack:
Elevated operating ambient temperature
— If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C)
specified by Extron.
Reduced air flow
— Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
Mechanical loading
— Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading
— Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Give appropriate consideration to the equipment nameplate ratings when addressing this
concern.
Reliable earthing (grounding)
— Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections to
the branch circuit (such as the use of power strips).
Rack Mounting the TLP 1000MV
The TLP 1000MV can be mounted in any standard 19-inch equipment rack, using the
optional Extron RM 1000M rack mounting kit (part number
70-886-01
). Follow the
instructions provided with the kit.
TLP 1000MV and TLP 1000TV • Mounting