SMX System MultiMatrix Switchers
• Front Panel Operation
3-13
Also refer to the
SMX System MultiMatrix Switchers User’s Manual
at www.extron.com.
Reset Levels
The rear panel has a recessed Reset button (see page 2-2,
c
) that
initiates four levels of resets (numbered 1, 3, 4, and 5). Use a
pointed stylus, ballpoint pen, or Extron Tweeker to access it and
enter the reset levels.
See the table on next page for a summary of the modes.
C
Review the reset modes carefully. Using the wrong
reset mode may result in unintended loss of flash
memory programming, port reassignment, or a
controller reboot.
N
The reset modes listed below close all open IP and Telnet
connections and close all sockets. Also, the following
modes are separate functions, not a continuation from
mode 1 to mode 5.
If the reset button is continuously held down, the I/O
lights blink every 3 seconds and enter a different reset
level, corresponding to modes 3, 4, and 5.
Reset mode uses
Use mode 1 to revert to the factory default firmware version if
incompatibility issues arise with user-loaded firmware.
See notes on next page.
Use mode 3 to restart the communication and control events.
Use mode 4 to reset most IP protocols to their default settings.
Use mode 5 to restore the switcher to the default conditions
.
N
Mode 5 reset clears most adjustments. To save these
settings, use the Windows-based SMX Control Program
and the
File
>
Save MATRIX settings as...
selection
before you perform this reset (see chapter 4, “SIS
Programmer's Guide”).
To reset the switcher:
RESET
RESET
RESET
RESET
Release, then
immediately
press and release again. Reset
LED flashes in confirmation.
Modes 3, 4, and 5
Press and
hold
the Reset button.
Mode 1
Reset LED flashes
once,
twice, or three times.
Press and
hold for
3, 6, or 9 seconds.
Apply Power
1
2
RESET
Release Reset button.