Cabling and Features

Attach cables using the following wiring diagrams as a guide. Full details are available in the 

IPCP Pro Series User Guide

.

CAUTION:
ATTENTION :

• 

Total length of the power cord including the small pigtail shall not be less than 1.5 m or more than 4.5 m.

• 

La longueur totale du câble d’alimentation, cordon compris, ne doit pas être inférieure à 1,5 m ou supérieure à 4,5 m.

• 

Always use the power cord provided with the unit.

• 

Veillez à toujours utiliser le câble d’alimentation fourni avec l’unité.

• 

Should you need to use a different power cord, consult Extron Electronics prior to using the cord.

• 

Si vous devez utiliser un autre câble d’alimentation, contactez Extron Electronics avant d’utiliser ce câble.

Power Input — Internal

 

R

POWER

50-60Hz

50-60Hz

100-240V ~ 10A MAX

100-240V ~ 10A MAX

INPUT

OUTPUT

Power Input, Internal Power Supply

• Front panel LED (    ) blinks 

during boot-up and remains lit 

when the IPCP receives power.

• Connect to 

100 to 240 VAC.

Rear Panel

Front Panel

6 inch (152 mm) 
IEC Input Cable

To a 100 - 240 VAC 

power source 

(main power)

IEC Power Cord

Power Output — Switched AC Power Output

 

R

POWER

Circuit Breaker 

(power output 

overcurrent 

protection)

Front 
Panel

10

PR

E

S

S

  

  T

O       R

E

S

E

T

BREAKER

50-60Hz

50-60Hz

100-240V ~ 10A MAX

100-240V ~ 10A MAX

INPUT

OUTPUT

Rear
Panel

Switched 100-240 VAC, 10 A (Max.) Power Output

• Front panel Power LED appears: 

• Lit green (    ) when power output is enabled (unit outputs power)
• Off (    ) when power output is disabled (power output is off)
• Lit red (    ) when a power output overcurrent condition is detected 

(the circuit breaker has been tripped) and power output is disabled.

• Front panel 

Power

 button controls power output availablity.

NOTE:

  The front panel power switch is not a safety disconnect 

device. In case of emergency, disconnect AC power from the 
power input (appliance inlet) of the connected equipment.

6 inch (152 mm) 
IEC Output Cable

Power input port 

on an AV device 

(international)

or

Power input port 

on an AV device

(USA)

IEC Power Cord

Edison Power Cord

NEMA 5-15R 

Adapter

NOTES:

• 

Within the United States of America use a power supply cord 
with conductors that are a minimum diameter of 18 AWG.

• 

For international installations, use a power supply cord with 
conductors that are a minimum of 1.0 mm

2

.

• 

Make sure that the device being controlled can support an 
AC power cycle.

CAUTION:

 

Always 
disconnect the 
product from 
the wall plug.

ATTENTION :

 

Veillez à toujours 
déconnecter le 
produit de la 
prise murale.

ATTENTION:

 

• 

When using the NEMA 5-15R receptacle 
adapter, connect the equipment only to a 
nominal 120 VAC electrical supply source.

• 

Lorsque vous utilisez la prise de courant 
NEMA 5-15R, veillez à ne connecter le 
dispositif qu’à une source d’alimentation 
nominale de 120 Vca.

Summary of Contents for IPCP Pro PCS1

Page 1: ... applications These control processors support multiple TouchLink Pro touchpanel interfaces over a standard Ethernet network The software applications are available at www extron com This guide provides instructions for an experienced installer to install an IPCP Pro PCS1 control processor and to create a basic configuration CAUTION This product is intended for indoor use only ATTENTION Ce produit...

Page 2: ... project and configuration If TouchLink Pro or third party touchpanels are part of the system start and use GUI Designer to design save and build the graphical user interface GUI layout for the touchpanels NOTE To redeem activate a LinkLicense go to www extron com llredeem and follow the online instructions Using GC create a new GC Professional or GC Plus project and configure the control processo...

Page 3: ...red control processor in the list and select it Network Communication Setup Connect the PC and the LAN port of the control processor to the same network Apply power to all devices Use the Set IP feature in Toolbelt or use the Toolbelt Manage Network Settings tab feature to enter the IP address and subnet address then configure other network settings as needed Figure 1 Network Setup Mounting Secure...

Page 4: ...nks three times to indicate the lockout mode has been enabled or disabled When the front panel is locked if the Power button is pressed the power LED blinks three times to indicate that the button is locked and the unit does not change power states as a result of the button press NOTE The executive mode state on or off persists after and is retained during a power cycle Circuit breaker The front p...

Page 5: ...0V 10A MAX INPUT OUTPUT Rear Panel Switched 100 240 VAC 10 A Max Power Output Front panel Power LED appears Lit green when power output is enabled unit outputs power Off when power output is disabled power output is off Lit red when a power output overcurrent condition is detected the circuit breaker has been tripped and power output is disabled Front panel Power button controls power output avail...

Page 6: ...ports Default login credentials Username admin Password extron IPCP IP address 192 168 254 250 Gateway IP address 0 0 0 0 Subnet mask 255 255 255 0 DNS address 127 0 0 1 DHCP client off Link speed and duplex level autodetected Data rates 10 100 1000Base T PC The control processor is assigned a unique user hardware ID number MAC address for example 00 05 A6 05 1C A0 You may need this address during...

Page 7: ...daisy chain star or combination Wire the connectors the same at both ends for every eBUS device See the eBUS Technology Reference Guide for the recommended distance from the control processor to the last eBUS device and maximum quantity of devices per control processor The IPCP Pro can provide power to the button panel devices Front Panel eBUS Limit LED amber Lights steadily and remains lit while ...

Page 8: ...n for about 3 seconds until the Power LED blinks once Release and press the Reset button momentarily for 1 second within 1 second Nothing happens if the momentary press does not occur within 1 second The LED blinks 2 times if the program is starting The LED blinks 3 times if the program is stopping This mode allows you to restart any programs stopped by an IP settings reset Toggle DHCP Client Pres...

Page 9: ...or the Extron S3 Control Systems Support Hotline 1 800 633 9877 Locating Software Firmware and Driver Files on the Extron Website There are three main ways to find software firmware and device drivers within www extron com Via links from the web page for the specific product Via the Download Center page Click on the Download tab at the top of any page within www extron com Via links from search re...

Page 10: ...chedules timers macros and local variables Add touchpanels or other interfaces if used to the project Configure ports on the control processor Import GUI layouts and configure the touchpanels or other interfaces Test the system make adjustments finalize configuration Save the project Build and upload the configuration to the control processor If desired or required install a new security certifica...

Reviews: