IPCP Pro PCS1 • Setup Guide

The Extron IPCP Pro PCS1 IP Link

®

 Pro Power and Device Control Processor integrates 

Ethernet connection into AV systems to allow users to remotely control and monitor 
AV equipment, including display devices and switchers. The IPCP Pro PCS1 features a 
controllable, 100-240 VAC, 50-60 Hz, AC power outlet for remote power management of 
a connected device. A 10 amp circuit breaker provides overcurrent protection.
The AC power button, located on the front panel, allows manual control of 
the AC power output port. A front panel security lockout mode (Executive 
Mode) can be used to disable the button if the unit is installed in an 
unsecured environment where access is undesirable. 
The IPCP Pro PCS1 includes an embedded web server, a bidirectional 
serial port, an IR/serial port, digital I/O, and a LAN port for use in 
applications that require control and monitoring of multiple devices within an AV system. It also includes an Extron eBUS

®

 port, 

which allows a variety of eBUS devices to be connected to a single control processor. eBUS devices include an array of button 
panels and power and signal hubs. eBUS devices are automatically recognized by the control processor and can be added or 
removed at any time.
To discover and manage the IPCP Pro control processor and other Extron control products, use Extron Toolbelt

®

 software. 

Configure the control processor using Extron Global Configurator

®

 software (Global Configurator Professional [GC Professional] 

or Global Configurator Plus [GC Plus]), or program the control processor using Extron Global Scripter

®

 (GS). The IPCP integrates 

seamlessly with Extron GlobalViewer

®

 Enterprise (GVE) software and Extron Control apps for remote control applications. These 

control processors support multiple TouchLink

®

 Pro touchpanel interfaces over a standard Ethernet network. The software 

applications are available at 

www.extron.com

.

This guide provides instructions for an experienced installer to install an IPCP Pro PCS1 control processor and to create a basic 
configuration.

CAUTION:

  This product is intended for indoor use only.

ATTENTION :

  Ce produit est exclusivement adapté à un usage intérieur.

NOTE:

  The IPCP Pro PCS1 is intended to be used with Extron Electronics products only.

Setup Checklist: How to Proceed With Installation

ATTENTION:

 

• 

Installation and service must be performed by experienced personnel.

• 

L’installation et l’entretien doivent être effectués par du personnel expérimenté.

Get Ready

 

…

Familiarize yourself with the features of the control processor (see 

Front Panel Features

 on page 4, 

Rear Panel 

Features

 on page 4) and of any TouchLink Pro touchpanels that will be part of the system.

 

…

Download and install the latest version of the following:

• 

Toolbelt software

 — for discovering the control processor and other control products on the network, for managing 

core settings, and for upgrading firmware when needed.

• 

Global Configurator (GC) software

 — for configuring the control system. 

• 

Global Scripter software

 — for programming the control processor (as an alternative to GC)

• 

GUI Designer software

 — for designing layouts for Extron TouchLink Pro touchpanels and third party touch interfaces

• 

IP Link Pro device drivers

 — for use with GC, to make control of AV devices possible

All are avail able from 

www.extron.com

 (see 

Locating Software, Firmware, and Driver Files on the Extron Website

 on page 9).

 

…

Obtain network information for the unit from the network administrator. You need the following details for each IP Link Pro device:

 

…

DHCP client setting (on or off)

 

…

Subnet mask

 

…

Username

 

…

Device (IPCP Pro, TouchLink Pro, IPL Pro) LAN IP address

 

…

Gateway IP address

 

…

Passwords

 

…

Write down the MAC address of each IP Link Pro device to be used.

 

…

Obtain model names and setup information for devices the IPCP will control.

10/26/18:  John Spencer wrote in the SharePoint review 

of rev. Ax8 of this guide, “I confirmed with  Homi that the 
“only to be used with Extron products” can change from a 
“Caution:” to just a note.”

Here’s the text used for the “CAUTION” version:

• 

The IPCP Pro PCS1 is intended to be used with 
Extron Electronics products only. 

• 

L’IPCP Pro PCS1 doit être utilisé exclusivement 
avec des produits Extron Electronics.

Summary of Contents for IPCP Pro PCS1

Page 1: ... applications These control processors support multiple TouchLink Pro touchpanel interfaces over a standard Ethernet network The software applications are available at www extron com This guide provides instructions for an experienced installer to install an IPCP Pro PCS1 control processor and to create a basic configuration CAUTION This product is intended for indoor use only ATTENTION Ce produit...

Page 2: ... project and configuration If TouchLink Pro or third party touchpanels are part of the system start and use GUI Designer to design save and build the graphical user interface GUI layout for the touchpanels NOTE To redeem activate a LinkLicense go to www extron com llredeem and follow the online instructions Using GC create a new GC Professional or GC Plus project and configure the control processo...

Page 3: ...red control processor in the list and select it Network Communication Setup Connect the PC and the LAN port of the control processor to the same network Apply power to all devices Use the Set IP feature in Toolbelt or use the Toolbelt Manage Network Settings tab feature to enter the IP address and subnet address then configure other network settings as needed Figure 1 Network Setup Mounting Secure...

Page 4: ...nks three times to indicate the lockout mode has been enabled or disabled When the front panel is locked if the Power button is pressed the power LED blinks three times to indicate that the button is locked and the unit does not change power states as a result of the button press NOTE The executive mode state on or off persists after and is retained during a power cycle Circuit breaker The front p...

Page 5: ...0V 10A MAX INPUT OUTPUT Rear Panel Switched 100 240 VAC 10 A Max Power Output Front panel Power LED appears Lit green when power output is enabled unit outputs power Off when power output is disabled power output is off Lit red when a power output overcurrent condition is detected the circuit breaker has been tripped and power output is disabled Front panel Power button controls power output avail...

Page 6: ...ports Default login credentials Username admin Password extron IPCP IP address 192 168 254 250 Gateway IP address 0 0 0 0 Subnet mask 255 255 255 0 DNS address 127 0 0 1 DHCP client off Link speed and duplex level autodetected Data rates 10 100 1000Base T PC The control processor is assigned a unique user hardware ID number MAC address for example 00 05 A6 05 1C A0 You may need this address during...

Page 7: ...daisy chain star or combination Wire the connectors the same at both ends for every eBUS device See the eBUS Technology Reference Guide for the recommended distance from the control processor to the last eBUS device and maximum quantity of devices per control processor The IPCP Pro can provide power to the button panel devices Front Panel eBUS Limit LED amber Lights steadily and remains lit while ...

Page 8: ...n for about 3 seconds until the Power LED blinks once Release and press the Reset button momentarily for 1 second within 1 second Nothing happens if the momentary press does not occur within 1 second The LED blinks 2 times if the program is starting The LED blinks 3 times if the program is stopping This mode allows you to restart any programs stopped by an IP settings reset Toggle DHCP Client Pres...

Page 9: ...or the Extron S3 Control Systems Support Hotline 1 800 633 9877 Locating Software Firmware and Driver Files on the Extron Website There are three main ways to find software firmware and device drivers within www extron com Via links from the web page for the specific product Via the Download Center page Click on the Download tab at the top of any page within www extron com Via links from search re...

Page 10: ...chedules timers macros and local variables Add touchpanels or other interfaces if used to the project Configure ports on the control processor Import GUI layouts and configure the touchpanels or other interfaces Test the system make adjustments finalize configuration Save the project Build and upload the configuration to the control processor If desired or required install a new security certifica...