Installation and Rear Panel, cont’d
IPL T PCS4 • Installation and Rear Panel
2-6
PRELIMINAR
Y
Connecting the Hardware
Connect the cables to the rear panel as follows:
1
.
Plug the Ethernet cable from your network into the LAN port on the rear
panel.
2
.
Plug the IPL T PCS4 power cord into a wall outlet. All front panel LEDs
flash on briefly; only the power and Ethernet LEDs remain lit. (No
receptacle lights should remain lit.)
A label covers the power receptacle on the IPL T PCS4 (U.S. version),
reminding you that you must use the supplied 14 AWG power cord for the
PCS4 to function properly. Remove this label before connecting the power
cord to the unit.
3
.
Plug the power cord of each device to be monitored into one of the
receptacles on the back panel of the PCS4.
4
.
If desired, connect a relay-controllable siren or other detection device to the
Alarm relay on the rear panel.
The alarm relay cannot be set up from the front panel. You must use either
SIS commands or the Web pages to configure it. See
Monitoring the
receptacles and setting the alarm
in chapter 4, or
Alarm relay
functions
in the SIS commands table in chapter 5.