5-5
IPL T PCS4 • SIS
™
Programming and Control
PRELIMINAR
Y
X16
=
Power-up delay between ports in 1/3 second
increments. 1-255 permitted. (Default is 3,
which equals 1 second.)
X18
=
Hardware (MAC) address (xx-xx-xx-xx-xx-xx).
X19
=
Subnet mask (xxx.xxx.xxx.xxx). Leading zeros
are optional in setting values in each of four
fields, and they are suppressed in returned
values.
X22
=
For Verbose/Response Mode:
0 = clear/none
1 = verbose mode
2 = tagged responses for queries
3 = verbose mode and tagged responses for
queries
Default = 0
If tagged responses is enabled, all read commands
return the constant string plus the data, like
setting the value does.
Example:
Command:
Esc
CN
Response: Ipn •
X12
X33
=
Password (minimum length = 4 characters;
maximum length = 12 characters. No special
characters are allowed.
X34
=
Daylight saving time (DST) is a 1-hour offset to
reflect the time during which clocks are set
one hour or more ahead of local standard
time, to provide more daylight at the end of
the working day. Supported for the U. S. and
parts of Brazil and Europe.
Example:
Time in California is GMT -8:00
from April to October and GMT -7:00 from
November to March.
DST should be turned off in Hawaii,
American Samoa, Guam, Puerto Rico, the
Virgin Islands, the eastern time zone portion
of the state of Indiana, and the state of
Arizona (excluding the Navajo Nation).
0 = off/ignore
1 = on
X41
=
Reading password. Responds with four asterisks
(****) in place of the password, if a password
exists. Responds with an empty space if no
password exists.
X45
=
E-mail event number (1 - 64)
X46
=
E-mail recipient’s address (e.g.,
)
for the person to whom messages will be
sent.
X47
=
Name (numeral) of e-mail file to be sent; e.g.,
1.eml, 2.eml, ... 64.eml
.
X49
=
Default name: a combination of the model name
and the last 3 pairs of the interface’s MAC
address (e.g., IPL-T-PCS4-00-02-3D).
X52
=
Connection’s security level
11 = user
12 = administrator
X63
=
Pulse time in 20 ms per count. If this parameter
is missing or = 0, then pulse length = default
(25 = 500 ms). 35565 ms = max. pulse time.
Symbol definitions
=
CR/LF (carriage line feed) (hex 0D 0A)
=
Soft carriage return (no line feed, hex 0D)
(For Web browser commands, use the
|
[pipe] character instead of the soft return.)
|
=
Pipe (vertical bar) character
•
=
Space
24
=
The
24
superscript indicates commands that give
an E24 (privilege violation) message if you
are not logged in at the administrator level.
Esc
=
Escape key (hex 1B)
(For Web browsers, use
W
instead of Esc. )
X1
=
Power receptacle ( 1-4)
X3
=
Greenwich Mean Time (GMT) offset value
(-12.00 to +14.00) represents the time
difference in hours and minutes (+/-hh:mm)
relative to Greenwich, England. The plus
sign and leading zero are optional. For
example, 5:30 = +05:30.
X5
=
On/off status
0 = off/disable
1 = on/enable
X6
=
Dirty memory status
1 = RAM needs to be saved to flash memory.
0 = RAM has been saved to flash (OK to
power off or reset).
X9
=
Current threshold sense
0 = clear/none
1 = standby
2 = full
(Full threshold must be set before standby.)
X10
=
Group number
0 = none
1 = yellow
2 = green
3 = red
(The exponent designates the port number.
The color relates to setting groups via the
front panel.)
X11
=
Version (typically listed to two decimal places,
e.g., x.xx)
X12
=
Unit name. The name of the PCS4 is a text
string of up to 24 characters drawn from the
alphabet (A-Z), digits (0-9), and minus sign/
hyphen (-). No blank or space characters are
permitted as part of a name. No distinction
is made between upper and lower case.
The first character
must
be a letter. The last
character must
not
be a minus sign/hyphen.
X13
=
Local date and time format
Set
format (MM/DD/YY-HH:MM:SS).
Example:
11/18/03-10:54:00.
Read
format (day of week, day month year
HH:MM:SS).
Example:
Tue, 18 Nov 2004 18:19:33.
X14
=
IP address (xxx.xxx.xxx.xxx). Leading zeros in
each of four fields are optional in setting
values, and they are suppressed in returned
values.
X15
=
E-mail domain name, e.g.,
extron.com
.