25
ENGLISH
J
FOR CORRECT OPERATION, SET TO AUX.
> SEE THE INSTALLATION CHAPTER SUPPLEMENTARY THERMOSTAT
stand By FunCtIon set to on
if the sTaND BY function is enabled (ON) and the room temperature exceeds the seT THer DeLTa T OFF value, then the stove
switches off after a preset factory delay, and sTaND BY will be displayed on the screen.
when the room temperature is lower than the seT THermOsTaT - DeLTa T ON value, and after a possible cooling time, the stove switches
back on.
stand By FunCtIon set to oFF (FaCtory settInG)
if the sTaND BY function is not active (OFF), if the stove exceeds the set room temperature it will switch to the minimum value, modulating
and displaying mODULaTiON. when the room temperature is lower than the seT THermOsTaT the stove will restart at the set power and
wOrK will be displayed on the screen.
oPeratIon wItH addItIonal tHermostat (oPtIonal)
stand By FunCtIon set to oFF
(FaCTOrY seTTiNg)
if the sTaND BY function is not active (OFF), if the stove exceeds the room temperature set on the additional thermostat (open contact) it will
switch to the minimum value, displaying mODULaTiON. when the room temperature is lower than the set value on the additional thermostat
(closed contact), the stove will resume operation at the set power, and wOrK will be displayed on the screen.
stand By FunCtIon set to on
when the sTaND BY function is activated (ON), when the room temperature set on the additional thermostat is reached (open contact), the
stove will switch off after a preset delay, and sTaND BY will appear on the screen.
when the room temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time,
the stove ignites again.
J
WHEN STAND BY AND AIR ZONE CONTROL ARE ACTIVE, THE GENERATOR IS SWITCHED OFF ONLY IF BOTH ROOMS
(INSTALLATION, DUCTING) REACH THE SET TEMPERATURE.
settInGs
•
DATE-TIME
•
LANGUAGE
•
DEGREES
SEE ChApTER: FIRST IGNITION SETTINGS
dIsPlay
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. if set to OFF, the display backlighting is set
to maximum brightness and turns off after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in the alarm condition.
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until seTTiNgs appears and confirm by pressing key 6.
Keep pressing key 3 until DisPLaY appears and confirm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
stand By
The sTaND BY function is used if the stove needs to be turned off immediately instead of a power modulation.
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until seTTiNgs appears and confirm by pressing key 6.
Keep pressing key 3 until sTaND BY appears and confirm by pressing key 6.
Use keys 4-5 to enable (
ON
) / disable (
OFF
).
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.