easy setuP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the easY seTUP function, it is possible to dose the pellets by increasing or decreasing the preset values.
in the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value which
is 0
if you notice an excessive deposit on the burn pot, access the easY seTUP program and lower the value by one unit to “- 1”; then wait until
the next day and if there is no improvement, decrease again, to a maximum of “- 3”. if, on the other hand, it is necessary to increase the pellet
dosage, switch the factory value from "0" to "+ 1, + 2, + 3" as required.
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until easY seTUP appears and confirm by pressing key 6.
Use keys 4 -5 to set the range.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
EXCESSIVE PELLET DEPOSIT IN BURN POT
NORMAL OPERATION
MINIMUM PELLET DEPOSIT IN BURN POT
-3
-2
-1
0
+1
+2
+3
THirD DeCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
seCOND
DeCrease
raNge iF
THe FirsT is
iNsUFFiCieNT
FirsT DeCrease
raNge (TesT FOr
1 DaY)
OPTimaL FaCTOrY
VaLUe
FirsT iNCrease
raNge
seCOND
iNCrease raNge
iF THe FirsT is
iNsUFFiCieNT
THirD iNCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
N.B.: IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT, PLEASE CONTACT YOUR LOCAL
SERVICE CENTRE.
aIr Zone Control (norIs Plus)
This menu allows you to enable the air ZONe CONTrOL mode
range: (ON, OFF)
if ON is selected, the stove will optimise the adjustments so that the heat is sent to the ducting when the main room temperature set is
reached.
CONTrOLs PrOCeDUre
Press key 6.
Press 3 until air ZONe CONTrOL appears and confirm by pressing 6.
Use keys 4--5 to enable (ON) or disable (OFF)
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
when the function is active, air ZONe CONTrOL appears on the display
WARNINGS: If the appliance is installed with air ducting active, but ambient probe or thermostat for air ducting (i.e. the jumper is
kept on the ducting terminal), and the
air ZONe CONTrOL
function is activated, it sends heat into the ducting regardless of the
temperature of the room receiving the ducting.
CHrono
This function allows stove ignition and switch-off to be automatically programmed.
The factory setting for CHrONO is off.
The chrono allows the programming of 4 time slots per day, which can be used every day of the week.
In each time slot, it is possible to set
the ignition and switch-off times, the days of use of the programmed time slot, the desired temperature (if
seT TemPeraTUre
) is
used and the set power. Current day and time settings are essential for the correct operation of the Chrono.
Recommendations
Before using the chrono function, you must set the current date and time, so check that you have followed the points listed in the sub-
chapter “
DaTe-Time
”. To use the chrono function correctly, it must not only be programmed, but also enabled. The 4 time slots can be
overlapped using the ignition and switch-off time settings. In this way, it is possible to create a combination of time slots with different
temperatures and power levels, without changing the status of the stove.
N.B.: in the case of overlapping time slots, the stove will remain on until the last switch-off time.