ENGLISH

CONTROL BOARD

vieWing oF various 

TexT messages

1

on/off stove.

2

increase operating power / scroll through the menus.

3

Decrease operating power / scroll through the menus.

4

increase operating thermostat set / scroll through the menus.

5

Decrease operating thermostat set / scroll through the menus.

6

To access the menu / confirm key.

ICON kEY

!

0

WI-FI

BT

STBY

OK

ON

indicates the presence of an alarm.

off: indicates there are no alarms 

on: indicates the presence of an alarm.

!

0

WI-FI

BT

STBY

OK

ON

Delayed switch-off icon.

off: deactivated.

on: activated.

!

0

WI-FI

BT

STBY

OK

ON

indicates the reception of the ir signal

on = ir command received

off = ir communication absent

!

0

WI-FI

BT

STBY

OK

ON

indicates the weekly programming status

off: deactivated.

on: activated.

The number indicates the current reference time frame.

!

0

WI-FI

BT

STBY

OK

ON

indicates contact of the external additional thermostat

closed contact: the contact of the external additional 

thermostat is closed.

open contact: the contact of the external additional 

thermostat is open.

!

0

WI-FI

BT

STBY

OK

ON

WiFi icon

off: deactivated.

on: activated and connected to the home network.

Flashing: activated but not connected to the home network.

!

0

WI-FI

BT

STBY

OK

ON

indicates the stove power.

Flame on: stable power.

Flame flashing: the power is changing.

The dashes indicate the actual power of the machine.

!

0

WI-FI

BT

STBY

OK

ON

sTanD-BY function icon

off: deactivated.

on: activated.

!

0

WI-FI

BT

STBY

OK

ON

it indicates the operation of the tangential fan.

off = ventilation not active.

on = ventilation active.

Flashing: ventilation at reduced speed for compensation.

!

0

WI-FI

BT

STBY

OK

ON

it indicates the operation of the pump.

off = pump stopped.

on = pump active.

Flashing = electronic anti-condensation function active.

Summary of Contents for COSTANZA IDRO

Page 1: ...MADE IN ITALY design production costanza IDRO 004277268 Rev 002 UK THERMO PRODUCTS USER MANUAL ...

Page 2: ...2 ENGLISH ...

Page 3: ... frequency 50 60Hz 23 Date time 23 Language 23 Degrees 23 Operation and logic 24 Additional thermostat 25 Additional thermostat functioning with STAND BY active 25 Additional thermostat operation with STAND BY deactivated 25 Additional thermostat installation 25 ventilation 26 easy setup 26 CHRONO 27 Enabling disabling the chrono 27 Settings 29 Display 29 stand by 29 First Load 29 OUTLET AIR 29 Wi...

Page 4: ...miques indiquées pour éviter des dégâts pour l alignement du top utiliser les 4 vis OBVEZNA POZORNOST Prije pomicanja peći uklonite označene pločice kako biste izbjegli oštećenja za poravnanje gornjeg dijela koristiti 4 vijka VORSICHT OBLIGATORISCH Bevor Sie den Ofen bewegen bitte unbedingt die bezeichnete Keramik Kacheln entfernen um Schäden zu vermeiden Verwenden Sie die 4 Schrauben um das obere...

Page 5: ...5 Silicone ENGLISH ...

Page 6: ...ance has been installed as well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was pur chased All electric components that make up the product must be replaced with original spare parts...

Page 7: ...E PRODUCT EVEN IF IT IS DISCONNECTED FROM THE MAINS It is advised to position the power supply cable so that it doesnotcomeintocontactwithhotpartsoftheappliance The power supply plug must be accessible after installation Do not close or reducethe dimensions ofthe airingvents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements withi...

Page 8: ...r effective authenticity To clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICALLY THANKS TO THETIMER ORREMOTELYUSINGTHEDEDICATEDAPPLICATIONS ITIS STRICTLY FORBIDDEN TO LEAVE ANY COMBUSTIBLE OBJECT WITHIN THE SAFETY DISTANCES INDICATED ON THE TECHNICA...

Page 9: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can also be installed in the cases indicated in points 1 2 and 3 of this paragraph Installations in bathrooms bedrooms and studio flats Installation in bathrooms bedrooms and studio flats is only allowed for...

Page 10: ... If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is inserted in an existing flue it must be certified for solid fuel If the smoke duct is outside the building it must always be insulated The smoke ducts must have at least one airtight inlet for flue gas s...

Page 11: ...This means that it is ideal for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly connected to the exterior using special pipes and sealed connectors FUMES EXHAUST SYSTEM If the generator has a fumes temperature of less than 160 C room temperature due to the...

Page 12: ...g and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation must be carried out by professionally qualified staff Ministerial Decree dated 22 01 08 n 37 Extraflame S p A declines all responsibility for damage to objects and or persons caused by the system Type o...

Page 13: ...e This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre existing flues is recommended ANTI CONDENSATION DEVICE MANDATORY Make sure a suitable anti condensate circuit has been realised which guarantees an appliance return temperature of at least 55 C The automatic thermostati...

Page 14: ...c installation T1 3 bar safety drain T2 Boiler flow output T3 Boiler return input Combustion air inlet Pellet hopper pressurised closure Door handle Fumes exhaust fuse Power supply 230v Access to the ash drawer Room air outlet Room air outlet Display Rearming ...

Page 15: ...onveying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenomenon due to filling Following filling the system must always be bled using the relevant vents in the circuit and having the machine perform the air vent function Following commissioning and with the mac...

Page 16: ...tovewillgointo DEPR ALARM mode while during normal operation the stove will go into COOLING WAITING TIME mode and then re start automatically when the correct conditions are present stove cold etc Stove positioning To ensure the stove works correctly it should always be positioned so that it is perfectly level using a spirit level REARMING Thefigurebelowshowstherearmposition 100 C Itisrecommended ...

Page 17: ...QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND MAY INVALIDATE THE WARRANTY AND FREE THE MANUFACTURER FROM RESPONSIBILITY pellet hopper pressurised closure During stove operation the pellet hopper lid must always be closed Keep clean Do not place the bag directly on the stove to load the tank Always use a scoop to load the tank Do not rub or place weights on the ta...

Page 18: ... On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay For example if you set it to one hour the stove will automatically switch off after the set time 11 Reset 6 Set room temperature 12 Battery compartment not available in this model ...

Page 19: ... receiver Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight or near a source of heat The quality of the signal may be affected by other IR sources Not available in this model Air mode selected Flashing COMFORT On AUTO Enable chrono Light on activated Light off dea...

Page 20: ...ect contact with water The touch screen display may not work properly in the presence of humidity or if it is exposed to water To avoid damaging the touch screen display do not touch it with sharp objects and do not press it too hard with your fingers During the opening and closing operation only press the display s external frame Touch sensitive parts FREQUENCY BANDS MAXIMUM POWER TRANSMITTED WiF...

Page 21: ...n activated The number indicates the current reference time frame 0 WI FI BT STBY OK ON Indicates contact of the external additional thermostat Closed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open 0 WI FI BT STBY OK ON WiFi icon Off deactivated On activated and connected to the home network Flashing activa...

Page 22: ...ystem must be completed in compliance with regulatory guidelines and the instructions in the manual The hopper must be loaded with pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the fire door and the ash drawer Check that the power cable is properly connected The bipolar switch in the rear right part must be positioned on 1...

Page 23: ...nfirm and key 1 to return to the previous menus to the initial state Language This menu allows the preferred language to be selected The languages available are Italian English German French Spanish Portuguese Controls procedure Press key 6 Press 3 until SETTINGS appears and confirm by pressing 6 Press 3 until LANGUAGE appears and confirm by pressing 6 Select the language with keys 4 or 5 Press ke...

Page 24: ...evel and increases the flue gas exhaust motor for a programmed period of time When the cleaning phase is finished the stove will re start automatically and continue the working phase returning to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to modulate automatically bringing itself to the minimum power If the temperature increase...

Page 25: ...nside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operation with STAND BY deactivated When the STAND BY function is not active the STBY icon will be off When the contact or external thermostat is satisfied open contact temperature reached the stove will go t...

Page 26: ...H THIRD INCREASE RANGE IF THE FIRST TWO ARE NOT ENOUGH Controls procedure Press key 6 Press key 3 until easy setup appears and confirm by pressing key 6 Use keys 4 and 5 to set the range Press key 6 to confirm and key 1 to return to the previous menus to the initial state N B If this calibration does not solve the pellet deposit in the burn pot please contact your local after sales centre ventilat...

Page 27: ...SET H2O PRG3 Power prg3 1 5 Set power PRG3 prg4 Start prg4 OFF 00 00 PRG4 start time Stop prg4 OFF 00 00 PRG4 stop time Monday Sunday On off Enabling disabling days for PRG4 Set prg4 65 C 80 C 149 F 176 F SET H2O PRG4 Power prg4 1 5 Set power PRG4 CHRONO This function allows the stove s ignition and switch off to be automatically programmed The factory setting for CHRONO is off The chrono allows t...

Page 28: ...0 t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 28 ENGLISH Time slot 1 start 02 00 stop 23 00 power 3 SET H2O 72 C Time slot 2 start 08 00 stop 16 30 power 1 SET H2O 68 C stove operation Time slot Set power SET H2O Example of chrono overlapping time slots ...

Page 29: ...e menu First Load This function allows to fill the auger facilitating the first start up phases of the stove or in the event that the pellet hopper is empty With the stove cold and OFF make sure the pellet has been introduced inside the tank and activate the FIRST LOAD function confirming with OK To interrupt continuous loading simply press key 1 for 3 seconds Controls procedure Press key 6 press ...

Page 30: ...l Wi Fi appears and confirm by pressing 6 Press 6 to access ENABLING Use keys 4 5 to select enabling ON disabling OFF and press 6 to confirm Press 1 several times to exit the menu HOME NETWORK CONFIGURATION procedure Press key 6 Press 3 until SETTINGS appears and confirm by pressing 6 Keep pressing 3 until Wi Fi appears and confirm by pressing 6 Press 3 until configuration appears and press 6 on t...

Page 31: ...er use abrasive or chemically aggressive detergents for cleaning The ceramic glass must only be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspaper dipped in ash If the glass is very dirty use a specific cleaning agent for ceramic glass Spray a small amount on a cloth and use it on the ceramic glass Do not spray the cleaning agent or ...

Page 32: ...r assembly Remove the burn pot Clean the combustion chamber and the bottom of the burn pot completely using a suitable vacuum cleaner THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES ONLY Details on burn pot cleaning To clean the burn pot it is necessary to remove the resistor assembly first Remove the resistor assembly by lifting it on one side before pulling it out see A B Remove the burn pot C Perform ...

Page 33: ...f they are worn or damaged These operations must be carried out by a qualified technician Connection to the flue Vacuum and clean the pipe that leads to the flue yearly or any time that it is necessary If there are horizontal tracts the residue must be removed before it can prevent the passage of the fumes Decommissioning end of season At the end of each season before turning the stove off it is a...

Page 34: ... replace and apply a new seal where required C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning E Check air intake pipe and cleaning of the flow sensor F Room air fan disassembly and removal of dust and pellet debris TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW LANORDICA EXTRAFL...

Page 35: ...mantle and clean the smoke duct and t new seal where required B Seals pallet hopper inspections ash drawer and door replace and apply a new seal where required C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning E Check air intake pipe and cleaning of the flow sensor F Room air fan disassembly and removal of dust and pellet deb...

Page 36: ...et TOFF Generator off waiting for re ignition due to all requests met Waiting Black out The generator is cooling after a power cut Once cooling is completed it will re start automatically Anti freeze The anti freeze function is in progress as the H2O temperature is below the factory set threshold the pump is active until the water reaches the pre set factory parameter 2 C Anti block The pump anti ...

Page 37: ...MAX H20 PRESSURE ALARM Air in the system Inadequate circulation Possible air in the system bleed the system Lack of adequate circulation Lack of or inadequate safety zone The water in the stove has exceeded 95 C Possible pump anomaly If the problem persists restore operations must be performed by an authorised technician h2o probe H2O probe fault Contact after sales centre DHW PROBE Fault in DHW p...

Page 38: ...ability to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarantee will be void Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee Similarly are excluded defects related to incorrect operation of the f...

Page 39: ...utlet pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product with the door open or if the glass is broken The product must be electrically connected to a system equipped with an operational earthing system Turn off the product in the event of a failure or ...

Page 40: ... kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local dealer to collect the waste electric or electronic appliance under the conditions and following the methods provided by national laws transposing the Directive 2012 19 EU Separate waste collection an...

Page 41: ...41 ENGLISH ...

Page 42: ...42 ENGLISH ...

Page 43: ...43 ENGLISH ...

Page 44: ...raflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the characteristics and the data reported in this pamphlet at any moment and without notice in order to improve its products This manual therefore cannot be regarded as a contract towards other parties ...

Reviews: