background image

AN340-EU-EN V1.3    4/13 

4

MODE

 

button

 

Momentary

 

press

 

to

 

step

 

through

 

the

 

available

 

modes:

 

air

 

velocity,

 

air

 

volume,

 

air

 

temperature,

 

relative

 

humidity,

 

wet

 

bulb

 

temperature,

 

dew

 

point

 

temperature.

 

 

AVERAGE,

 

MAXIMUM,

 

MINIMUM,

 

and

 

ENTER

 

button

 

Press

 

to

 

view

 

average/minimum/maximum

 

readings.

 

Also

 

used

 

to

 

confirm

 

(enter)

 

a

 

selection

 

while

 

programming.

 

 

START,

 

ESC

 

button

 

In

 

the

 

normal

 

operating

 

mode,

 

press

 

and

 

hold

 

for

 

two

 

(2)

 

seconds

 

to

 

start

 

or

 

stop

 

the

 

automatic

 

datalogger.

 

Also,

 

press

 

to

 

exit

 

(escape)

 

AVG/MIN/MAX,

 

RECALL,

 

and

 

SETUP

 

modes.

 

 

HOLD,

 

UP

 

ARROW

 

button

 

In

 

the

 

normal

 

mode,

 

press

 

to

 

freeze/un

freeze

 

the

 

displayed

 

reading.

 

It

 

is

 

also

 

used

 

to

 

move

 

UP

 

in

 

a

 

menu

 

list.

 

 

LW

D

A

 

(LENGTH/WIDTH

DIAMETER

AREA)

 

button

 

In

 

the

 

Air

 

Volume

 

mode,

 

press

 

this

 

button

 

to

 

begin

 

programming

 

the

 

AREA

 

value

 

for

 

the

 

duct

 

under

 

test.

 

This

 

button

 

is

 

also

 

used

 

to

 

move

 

DOWN

 

a

 

menu

 

list.

 

 

MEM

RECALL

 

button

 

In

 

the

 

normal

 

mode

 

of

 

operation,

 

press

 

this

 

button

 

to

 

manually

 

record

 

a

 

reading

 

into

 

the

 

meter’s

 

99

 

location

 

memory.

 

Press

 

and

 

hold

 

for

 

two

 

(2)

 

seconds

 

to

 

recall

 

and

 

review

 

the

 

manually

 

recorded

 

data

 

one

 

reading

 

at

 

a

 

time.

 

 

and

 

 

With

 

the

 

meter

 

OFF,

 

press

 

and

 

hold

 

these

 

two

 

buttons

 

to

 

disable

 

the

 

sleep

 

mode.

 

Sleep

 

mode

 

switches

 

the

 

meter

 

off

 

automatically

 

after

 

a

 

twenty

 

(20)

 

minute

 

period

 

of

 

inactivity.

 

and

 

 

With

 

the

 

meter

 

OFF,

 

press

 

and

 

hold

 

these

 

two

 

buttons

 

until

 

PC

 

appears

 

on

 

the

 

LCD.

 

The

 

meter

 

is

 

now

 

ready

 

to

 

communicate

 

with

 

a

 

PC.

 

For

 

instructions

 

on

 

the

 

use

 

of

 

the

 

PC

 

interface

 

please

 

refer

 

to

 

the

 

HELP

 

utility

 

provided

 

on

 

the

 

supplied

 

CD

ROM.

 

 

Shop for Data Logging products online at:   

www.

DataLoggerStore

.com   

1.877.766.5412

Summary of Contents for AN340

Page 1: ...USER GUIDE Mini Vane CMM CFM Anemometer Psychrometer Datalogger Model AN340 Shop for Data Logging products online at www DataLoggerStore com 1 877 766 5412 ...

Page 2: ...Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support CAUTIONS Improper use of this meter can cause damage to the meter and personal injury Read and understand this user manual before operating the meter Inspect the condition of the probe and the meter for any damage before operating the meter Repair or replace damage before...

Page 3: ... 10 LW D A and down arrow button 11 Mini Vane impeller 12 Temperature and humidity sensors 13 Telescoping sensor arm Note Battery compartment not shown is located on rear of instrument Meter Top Description 1 Sensor connection jack 2 AC power adaptor jack 3 USB PC interface jack Keypad Description POWER ON OFF and SET button Press momentarily to power meter ON or OFF Press and hold for two 2 secon...

Page 4: ... In the Air Volume mode press this button to begin programming the AREA value for the duct under test This button is also used to move DOWN a menu list MEM RECALL button In the normal mode of operation press this button to manually record a reading into the meter s 99 location memory Press and hold for two 2 seconds to recall and review the manually recorded data one reading at a time and With the...

Page 5: ...ents o C F Temperature units TA Air Temperature RH Relative Humidity DP Dew point WBT Wet bulb VEL Velocity VOL Volume HOLD Display HOLD feature rh Relative Humidity unit of measure m s Meters per second ft m Feet per minute CFM Cubic feet per minute CMM Cubic meters per minute REC Record RECALL Recall AM PM Morning Evening time B Low Battery 8888 8 Main larger and upper display digits 88 88 88 Ti...

Page 6: ... temperature Note that for air volume measurements the user must first enter the area value for the duct under test before accurate readings can be made Refer to the AREA section of this guide for programming details and to the Appendix for additional information on area measurements calculations and unit conversions 7 When measuring air must enter the vane on the side of the sensor with the print...

Page 7: ...ng encountered since the mode was accessed 2 Press AVG MAX MIN again to display the maximum reading encountered The MAX icon will appear on the LCD and the reading displayed indicates the highest reading encountered 3 Press AVG MAX MIN again to display the average of all reading encountered The AVG icon will appear on the LCD 4 Press AVG MAX MIN again and the display will return to displaying real...

Page 8: ...d software program in order for the readings to be read and analyzed 1 Press and hold the START ESC button for two 2 seconds to start the datalogger Readings will be logged at the sampling rate selected by the user in the SETUP mode The REC icon will flash while the meter is automatically logging 2 All parameters velocity volume dew point wet bulb and humidity will be logged regardless of which pa...

Page 9: ... more information From the normal operating mode use the MODE button to scroll to the Air Volume mode Use the LW D A button to select the method LW LENGTH x WIDTH for rectangular ducts D DIAMETER for circular ducts or A AREA if the area value is known The display icons L D and A inform the user as to which mode is selected LENGTH x WIDTH Area Mode When the L is shown at the top of the LCD the mete...

Page 10: ...rate air volume flow in CMM CFM units Entering the AREA Value Manually When the A is shown at the top of the LCD the meter is ready to accept an Area value directly in square centimeters or square inches cm 2 or inch 2 Note Use the LW D A button from the Air Volume measurement mode to access the A screen if necessary Use the button ONLY to change the value of the flashing digit pressing the down a...

Page 11: ...ow keys to step to another parameter or press ESC to exit the SETUP mode P20 CLR 99 Reading Memory Clear 1 Once in the setup mode at the P20 CLR display momentarily press the ENTER button to access the P20 menu 2 The word NO or YES will be flashing Use the arrow keys to select NO do not erase data or YES erase data When the desired command is shown press the ENTER button to execute the command If ...

Page 12: ...w RTC again and the lower display the time in HH MM SS format The HH digits should now be flashing Use the arrow buttons to select the current hour and then press ENTER to confirm 7 The MM digits should be flashing Use the arrow buttons to select the current minute and then press ENTER to confirm 8 The SS digits should now be flashing Use the arrow buttons to select the seconds and then press ENTE...

Page 13: ...ver dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point fo...

Page 14: ... F 32 to 122 F 2 2 F below 32 F above 122 F Circuit Custom LSI microprocessor Display Dual function 32 5 H x 54 W mm 1 3 x 2 1 LCD Sampling rate 1 reading per second approx Air velocity flow sensor Angled mini vane arms with low friction ball bearing Sensors NTC type precision thermistors Automatic Power off Auto shut off after 20 minutes to preserve battery life sleep mode Operating Temperature 0...

Page 15: ...w range limit Test the meter in an environment known to be within acceptable meter limits If error persists send the unit to Extech for repair E3 Error No field solution Return the unit to Extech Instruments for repair E4 Error The reading is higher than the high range limit Test the meter in an environment known to be within acceptable meter limits If error persists send the unit to Extech for re...

Page 16: ...508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com Area A Length L x Width W CFM ft 3 min Air Velocity ft min x Area ft 2 CMM m 3 min Air Velocity m sec x Area m...

Reviews: