9
Note:
If the green LED is not lit or flashing in DMX mode, then the Jet isn't getting a valid signal. In
this case you should check the connection to the Jet, as well the settings at the DIP
switches.
The opening time in DMX-mode, which is set using channel 2, has no deeper connection to
the opening time set for the external ignition in mastermodule mode. Use exclusively the
formula and table on the previous page to set the opening time in DMX-mode!
Note the following for the value of the lever:
Lever value channel2
(Opening time)
Description
1-10
Not usable, safety
11 - 200
CO²-Jet-Function:
The values in this zone can be used
to set the opening time.
Minimum:
value 11 = 20ms
Maximum:
value 200 = 3800ms
201 - 250
Duration function:
If the channel is set in this zone, the
device will be opened permanently.
251 - 255
Not usable, safety
Only after setting the opening time, the CO²-Jet can be activated, by pushing channel 1 over
it's value 253 (meaning 254 or 255).
LED Status signals in DMX mode:
•
As soon as the CO²-Jet gets a signal, the green LED will begin flashing.
•
If the second channel is changed, the green LED will be lit permanently.
•
If the first channel is pushed above value 100, the red LED will be lit.
Examples for opening times:
5