Pg.
7
WARNING:
The output voltage of this unit must never be
connected in its input AC terminal, overload
or damage may result. Always switch on the
inverter before plugging in any appliance.
Wiring Guide
DC Wiring Connection
It is recommenced that the battery bank be kept as close as possible to the inverter.
The following table is a
suggested fuse and wiring guide
for a 3 ft cable. If wiring is
longer than 3 ft, please increase the diameter (AWG) of cable for stability and safety.
Cable Size, Material, and Safety
Model
Wire Gauge / Min
Battery Voltage
Fuse Size
0~3 ft
3~16 ft
2000W
12 Vdc
12 Vdc
300A
400A
0 AWG
3/0 AWG
3000W
3/0 AWG
4/0 AWG
AC Wiring Connection
This connection method is completely optional. We recommend using 10 -12 AWG
wires for AC terminal block connection. The diagram below shows an example of
both AC input and output
being used. This inverter charger
can also be used with
just AC input or output connection
depending on your needs. Please contact our
support team if you are unsure how to wire any part of your inverter.
110V Single Phase
•
Slightly unscrew the first row of
screws to open the wire clamp.
•
Insert exposed wire segment
into the bottom opening.
•
Tighten the screw back in while
the exposed wire segment is
inserted. Ensure all wires are
properly fastened.
AC Terminal Block Wiring:
AC INPUT WIRE
AC OUTPUT WIRE
SHORE POWER
AC APPLIANCES
AC BREAKER BOX
AC INPUT
AC OUTPUT
110V Connection Guide
Live / Hot
Neutral
Earth / Ground
Summary of Contents for IVOCH2KW
Page 22: ...Pg 21 Notes ...
Page 23: ...Pg 22 ...