Connecting Battery Bank
Pg.
8
•
The stability and safety of this product can be improved by using one shorter-
thicker cable. Therefor, if in doubt, round up in wire size and keep the length as
short as possible. Another important aspect of your power system is to take into
consideration the cable material. We highly recommend that you use only coper
cables for your wiring needs as they are the gold standard for this type of product.
•
Unscrew the top plastic screw on
the protective plastic cover.
•
Remove protective plastic cover to
get access to the positive and
negative terminals.
•
Unscrew the metal bolt and remove
both washers.
Grounding Your Inverter
Grounding is an important step for any electrical system and is highly recommended.
Grounding your electrical system can help with safety and to prevent faults. It is also a
requirement for certain Local and National Electric Codes (NEC). Please consult with
NEC for more information on this subject regarding local regulations and suggestions.
Grounding Your System
•
The recommended wire size for grounding this inverter is an
8 AWG copper wire
.
•
Connecting to ground must be done via the available
grounding cables for house applications or to the metal frame
of an RV for mobile home applications.
•
Attach the Battery Pack Cables to the
appropriate terminal, place washers
over the cable, and screw the bolt
back on firmly.
•
Return the protective plastic cover and
fasten it back on with the plastic screw.