Alarm Indications
Pg.
12
Alarms, Behavior, & Display
Fan Protection
When heat sink temperature goes over 221ºF, the inverter
shuts down after 30 seconds.
Over Temperature Protection
Yes
Back-Feed Protection
Restarts the inverter.
Recover From Fault Shutoff
Alarms & Protections
Buzzer beeps every 5s. Then inverter
shutoff after 60s.
High Battery Voltage
Buzzer beeps every 5s.
Low Battery Voltage
When heat sink temperature goes over
221ºF buzzer beeps every 5s.
Over-Temperature
Audio Alarm Behavior
Fault
2000W Model 3000W Model
Inverter
Overload
2200 - 2500W
Beeps every 1s after 14 min., and
inverter shutoff after the 15
th
min.
2500 - 3000W
Beeps every 1s, and inverter shutoff
after 60s.
3000W
Beeps every 1s, and inverter shutoff
after 20s.
3300 - 3750W
3750 - 4500W
4500W
Alarm LED
ON
ON
Flashes
None
Summary of Contents for IVOCH2KW
Page 22: ...Pg 21 Notes ...