19
MANUGENETOP6xx
Operating Instructions
VER 1.03
5.3 Optional plugin module
eTOP600 serie panels have several optional plugin module, multiple modules configurations are possible.
Slot#2 and Slot#4 are available only if plugin module has the “bus extension connector”.
Each slot carries three communication channels:
•
1 serial interface
•
1 CAN interface
•
1 SPI interface
Note: It is not possible to stack two modules that are using the same type of interface.
Below you can find relation between modules ATEX and IECEx marked and max number of modules
that can be used into eTOP600 serie panels, based on their Interface Type:
Module
Application
Max Modules
Interface Type
Bus Extension
connector
PLCM01
CAN
1 for eTOP507G
2 for eTOP507MG
CAN
Y
PLCM01-NE
CAN
1 for eTOP507G
2 for eTOP507MG
CAN
N
PLCM05
CODESYS
License
1
Y
PLIO03
Multifunction I/O
1
SPI
N