 1. Product information

1.1 Function

Use

 

The 

exodraft

 model RS chimney fan is a chimney top mounted ventilator that is designed to provide large flue 

gas

 

volume capacities.

 

It is designed and intended for use with residential gas or oil fired central space heating 

systems, for volume water heating or for combination space heating/volume water heating. It is also suitable for

 

use with gas-fired fireplaces, stoves, BBQ’s or residential pizza ovens. 

 

This product is developed to prevent draft problems from occurring by creating a mechanical draft in venting

 

systems and thereby also increasing the capacity and efficiency of a venting system.

 

The use of the RS Chimney Fan is not restricted to any type of chimney, because the fan creates a

 

negative 

pressure (below atmospheric) in the chimney or vent.

 
Code compliance  

Installations must conform to requirements of the authority having jurisdiction.

 

All electrical wiring must be in accordance with the requirements of authority having jurisdiction.

Listing  

The RS is tested and listed to UL Standard 378, Standard for Draft Equipment. The fan is manufactured at an 

ISO9001 certified plant and bears the European CE compliance label.

 

The chimney fan must be interlocked with the connected appliance(s) to insure proper combustions and to 

avoid flue gas spillage.

1.2 Shipping

The packing list (attached to one of the packages) clearly lists all items in the shipment and each package has a

 

label showing the 

contents.

 

Check the list against all materials on the job site for completeness.

 

NOTE: All single phase fans are shipped with a capacitor and junction box connected via conduit. The 

capacitor is located INSIDE the junction box. Please do not discard.

1.3 Warranty

2-Year Factory Warranty 

We promise the original user that we will replace or repair as we may elect, any part or parts of the new RS Chimney Fan which are 

defective in material or workmanship without charge for parts and labor (not including labor for dismantling and installation, freight, 

etc.) during the first 2-years following the date of invoice. 

10-Year Corrosion Perforation Warranty 

We promise the original user that we will replace or repair as we may elect, any part or parts of the RS Chimney Fan which are 

perforated due to corrosion without charge for parts or labor (not including dismantling and installation, freight, etc.) during the first 

10-years following the date of invoice.

Complete warranty conditions are available at www.exodraft.com or request a copy at:

[email protected] or at tel: +45 7010 2234

3

3000270  RS gas and oil 20210818 - international

Summary of Contents for RS 009

Page 1: ...ation Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUCTIONS R...

Page 2: ...g place 5 This unit must be grounded How to use this manual This installation manual does not contain any system design documentation System design documentation is available from exodraft Accessories...

Page 3: ...ney fan must be interlocked with the connected appliance s to insure proper combustions and to avoid flue gas spillage 1 2 Shipping The packing list attached to one of the packages clearly lists all i...

Page 4: ...4 422 478 C in 10 8 13 5 15 5 17 4 mm 275 344 395 441 D in 3 0 3 3 3 9 3 9 mm 75 85 100 100 E in 9 4 11 6 13 5 15 4 mm 238 294 342 391 Temperature Rating Interm 575 F 300 C Cont 482 F 250 C Capacity 1...

Page 5: ...st be provided for combustion otherwise improper operation and inadequate venting of deadly flue gases may result Support system for the exodraft chimney fan Prior to installation of the chimney fan i...

Page 6: ...hroat of the fan the hole in the fiber mat should correspond to the throat Step 2 Preparation of fan y Locate the installation brackets in the grooves on the underside of the fan base using the bolts...

Page 7: ...that the bolts shall be installed from the bottom side in the two inner holes y Adjust the final position of the brackets ensuring that there is clearance between the brackets and the flue wall If the...

Page 8: ...e and bolted onto the top When installing multiple fans it is extremely important that the fans are of the same model and size and they must be controlled in tandem by one 1 motor speed control y A si...

Page 9: ...lation of Proven Draft Switch PDS y A safety system must be interlocked with the appliance s The safety system could utilize a Proven Draft Switch a thermal switch or a flow switch The device must be...

Page 10: ...same temperature rating Otherwise insulation may melt or degrade exposing bare wire 4 2 Wiring diagram for single fan with fan speed control The wiring diagram below shows the wiring of the chimney fa...

Page 11: ...ng must be in flexible or rigid metal conduit LEGEND 24 VAc 120 VAC WEATHERPROOF BOX N FAN SPEED CONTROL ORANGE RED WHITE BLACK GREEN FAN MOTOR WEATHERPROOF BOX ORANGE WEATHERPROOF BOX L 24V GAS VALVE...

Page 12: ...here in the system Check the system for flue gas spillage Mark this setting on the fan speed control cover 5 3 Adjusting the Proven Draft Switch setting y Remove the snap on cover from the conduit enc...

Page 13: ...housing unless power to the chimney fan has been disconnected 6 3 Chimney cleaning intervals It is extremely important to keep the chimney flue clean from products of combustion and deposits Soot can...

Page 14: ...eed control There is power to the fan but it hums and does not turn The motor run capacitor may be bad Creosote may stick Check capacitor and replace if necessary Clean fan The fan seems to work fine...

Page 15: ...Notes 15 3000270 RS gas and oil 20210818 international...

Page 16: ...www exodraft com Notes...

Reviews: