6.4 Troubleshooting

Observation

Problem

Solution

There is no power going to 

the fan

• The circuit breaker may be off
• Fan speed control is off
• Bad electrical connections

• Check the circuit breaker
• Turn fan speed contron on
• Check and correct problem

There is power to the fan but 

it is not operating

• Bad electrical connections

• The fan speed control’s low 

voltage setting is too low
• The fan speed control is bad

• Check and correct problems with connections.  

Pay special attention to the wiring in the junction box

• Increase the setting with the plastic screw on the fan speed 

control’s front plate

• Replace the fan speed control

There is power to the fan but 

it hums and does not turn

• The motor run capacitor may be 

bad.
• Creosote may stick

• Check capacitor and replace if necessary

• Clean fan

The fan seems to work fine, 

but there is not enough draft

• The fan may be undersized
• Obstruction in the flue

• Replace with a larger fan
• Clean the chimney

The fan vibrates

• The motor shaft may be bent
• The hinges may be bent

• Replace motor
• Straighten out hinges

There is airflow noise from 

the draft hood

• The flue is undersized.
• The fan is oversized and running 

too fast

• There is not much to do about it
• Reduce the fan speed

Mechanical noise can be 

heard

• Foreign matter may be stuck
• Motor bearings may be worn out

• Remove matters
• Replace bearings

Service: [email protected] or at tel: +45 7010 2234

14

3000270  RS gas and oil 20210818 - international

Summary of Contents for RS 009

Page 1: ...ation Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUCTIONS R...

Page 2: ...g place 5 This unit must be grounded How to use this manual This installation manual does not contain any system design documentation System design documentation is available from exodraft Accessories...

Page 3: ...ney fan must be interlocked with the connected appliance s to insure proper combustions and to avoid flue gas spillage 1 2 Shipping The packing list attached to one of the packages clearly lists all i...

Page 4: ...4 422 478 C in 10 8 13 5 15 5 17 4 mm 275 344 395 441 D in 3 0 3 3 3 9 3 9 mm 75 85 100 100 E in 9 4 11 6 13 5 15 4 mm 238 294 342 391 Temperature Rating Interm 575 F 300 C Cont 482 F 250 C Capacity 1...

Page 5: ...st be provided for combustion otherwise improper operation and inadequate venting of deadly flue gases may result Support system for the exodraft chimney fan Prior to installation of the chimney fan i...

Page 6: ...hroat of the fan the hole in the fiber mat should correspond to the throat Step 2 Preparation of fan y Locate the installation brackets in the grooves on the underside of the fan base using the bolts...

Page 7: ...that the bolts shall be installed from the bottom side in the two inner holes y Adjust the final position of the brackets ensuring that there is clearance between the brackets and the flue wall If the...

Page 8: ...e and bolted onto the top When installing multiple fans it is extremely important that the fans are of the same model and size and they must be controlled in tandem by one 1 motor speed control y A si...

Page 9: ...lation of Proven Draft Switch PDS y A safety system must be interlocked with the appliance s The safety system could utilize a Proven Draft Switch a thermal switch or a flow switch The device must be...

Page 10: ...same temperature rating Otherwise insulation may melt or degrade exposing bare wire 4 2 Wiring diagram for single fan with fan speed control The wiring diagram below shows the wiring of the chimney fa...

Page 11: ...ng must be in flexible or rigid metal conduit LEGEND 24 VAc 120 VAC WEATHERPROOF BOX N FAN SPEED CONTROL ORANGE RED WHITE BLACK GREEN FAN MOTOR WEATHERPROOF BOX ORANGE WEATHERPROOF BOX L 24V GAS VALVE...

Page 12: ...here in the system Check the system for flue gas spillage Mark this setting on the fan speed control cover 5 3 Adjusting the Proven Draft Switch setting y Remove the snap on cover from the conduit enc...

Page 13: ...housing unless power to the chimney fan has been disconnected 6 3 Chimney cleaning intervals It is extremely important to keep the chimney flue clean from products of combustion and deposits Soot can...

Page 14: ...eed control There is power to the fan but it hums and does not turn The motor run capacitor may be bad Creosote may stick Check capacitor and replace if necessary Clean fan The fan seems to work fine...

Page 15: ...Notes 15 3000270 RS gas and oil 20210818 international...

Page 16: ...www exodraft com Notes...

Reviews: