2.3.1
For the United States and Canada
In the United States and Canada the male plug is a NEMA5-15 style (Figure A2, above), UL Listed, and
CSA Labeled. For units which are mounted on a desk or table, SVT or SJT type cord sets may be used.
For units which sit on the floor, only SJT type cord sets may be used. The cord set must be selected
according to the current rating for your unit. Please consult the table below for the selection criteria for
power cords used in the United States and Canada.
Code Type
Size of Conductors in Cord
Maximum Current Rating of Unit
SJT
18 AWG
16 AWG
14 AWG
10 Amps
12 Amps
12 Amps
SVT
18 AWG
17 AWG
10 Amps
12 Amps
2.3.2
For European Countries
In Europe you must use a cord set which is appropriate for the receptacles in your country. The cord set is
HAR-Certified, and a special mark that will appear on the outer sheath, or on the insulation of one of the
inner conductors.
2.3.3
For the United Kingdom
For your safety please read the following text carefully.
If the fitted molded plug is unsuitable for the socket outlet, then the plug should be cut off and disposed of
safely.
DANGER
Do not plug the cut-off plug into a socket outlet! There is a danger of severe
electrical shock!
If a new plug is to be fitted, please observe the wiring code as shown below. In case of doubt, please
consult a qualified electrician.
WARNING
This appliance must be earthed (grounded).
IMPORTANT
The wires in this mains lead are colored in accordance with the following codes:
Green-and-Yellow : Ground (Earth)
Blue : Neutral
Brown : Live