Installation
5/12
2.
Installation
All installations must be carried out by competent personnel in
accordance with local laws and regulations.
Isolation switch
•
An isolation switch must be installed between the controller and
the chimney fan.
•
For installation of the isolation switch please consult the
installation instructions for the chimney fan.
•
The isolation switch is not supplied by EXHAUSTO.
The control panel is to be installed on a level surface with a minimum distance of 100
mm to any corner.
The front cover is removed from the frame by twisting a screw driver in the two holes on
the sides of the front cover. The front cover can then be tipped carefully and the frame
can be mounted on the wall.
Notice
The front cover is mounted with a connection ribbon cable in the right side, which results
in a restricted opening of this side.
The assembling part of the IR-sensor, the black cable, may not be bend.
The control box covers a standard single back box.(Not EXHAUSTO supply)
.
•
Installation of the power supply wire must be carried out in
accordance with local laws and regulations.
•
The earth wires must always be connected.
•
Before the appliance a fused switch must be present that
completely disables power to the appliance. The switch must
always be switched off when the appliance is not in use.
2.1 Installation of control panel and external IR-sensor
Fig. 3
Fig. 4
110
65
Fig. 5
2.2 Power supply