background image

EXHAUSTO

 3001736-2004-01-21.fm

Installation

 

6/12

Description

The example shows how to connect the EFC25 directly to the fireplace control. This 
installation demands a fire with a control unit which has flame detection and automatic 
ignition. In case of insufficient flue gas flow (controlled by the PDS in the fan) the 
fireplace control will be disconnected, by means of a voltage free contact. 

Connect the earth wires between power supply and chimney fan

Connect the chimney fan and pressure switch to terminals 1-5

Connect the start/release signal for the burner control to terminals 12-13 (voltage 
free contact)

Connect Step 2 signal (if any) to terminals 14-15 (voltage free contact)

Connect the power supply to the terminals marked ”Power”.    

Diagram

Application

2.3 Standard installation

Fig. 6

Chimney fan w/PDS

Isolation switch

EFC 25

Gas

Power supply

Fig. 7

Fireplace control

Fused switch

Summary of Contents for EFC 25

Page 1: ...EXHAUSTO A S Odensevej 76 DK 5550 Langeskov Tlf 45 65 66 12 34 Fax 45 65 66 11 10 exhausto exhausto dk www exhausto com EXHAUSTO 3001736 2004 01 21 fm Installation operating instructions EFC 25 GB...

Page 2: ...ut this manual to bring attention to the presence of potential hazards or important information concerning the product DANGER Indicates an imminently hazardous situation which if not avoi ded will res...

Page 3: ...fan will immediately start up on full speed When the fail safe supervision confirms sufficient chimney draught the fireplace will be lit and the fan speed will adjust to the pre set value correspondi...

Page 4: ...spare fuse included in control box M Terminals for Step 2 E PDS pressure differential switch terminals N Terminals for start signal to fireplace control F Terminals for chimney fan O Terminals for fre...

Page 5: ...les on the sides of the front cover The front cover can then be tipped carefully and the frame can be mounted on the wall Notice The front cover is mounted with a connection ribbon cable in the right...

Page 6: ...e disconnected by means of a voltage free contact Connect the earth wires between power supply and chimney fan Connect the chimney fan and pressure switch to terminals 1 5 Connect the start release si...

Page 7: ...ontact Connect the earth wires between power supply and chimney fan Connect the chimney fan and pressure switch to terminals 1 5 Connect the external ON OFF switch to terminals 8 9 Connect the start r...

Page 8: ...passed Open control panel Press ON OFF button Fig 1 C Wait until constant green light if the fire has to be lit during commissioning Press the service mode button Fig 1 H on reverse of front cover The...

Page 9: ...connected the operation LED changes to GREEN Set the PDS to 10 Pa below the registered value of disengagement Press the ON OFF button Fig 1 C and the control turns off the service mode Check the star...

Page 10: ...the fireplace will get a signal to fire To stop the fire and fan press the ON OFF button fig 10 F Operation from external ON OFF switch The ON OFF switch can be used for start stop and reset of the co...

Page 11: ...Check settings and redo commissioning Flashing YELLOW No signal from air inlet 1 Re connect loop on terminal 10 11 FlashingRED GREEN or YELLOW Flashing RED Service mode on 1 Press ON OFF button No re...