background image

EXHAUSTO

 3001736-2004-01-21.fm

EXHAUSTO A/S

Odensevej 76
DK-5550  Langeskov
Tel.: +45 6566 1234
Fax: +45 6566 1110
E-mail: [email protected]
www.exhausto.dk

EXHAUSTO GmbH

Am Ockenheimer Graben 40
D-55411  Bingen-Kempten
Tel.: +49 6721 9178-0
Fax: +49 6721 9178-99
E-mail: [email protected]
www.exhausto.de

EXHAUSTO NORGE A/S

Lilleakerveien 4
N-0283  Oslo
Tel.: +47 2412 4200
Fax: +47 2412 4201
E-mail: [email protected]
www.exhausto.no

EXHAUSTO Ltd.

Unit 3 Lancaster Court,
Coronation Road,
Cressex Business Park
GB-High Wycombe HP12 3TD Tel.: 
+44 1494 465166
Fax: +44 1494 465163
E-mail: [email protected]
www.exhausto.co.uk

EXHAUSTO AB

Verkstadsgatan 13
S-542 33  Mariestad
Tel.: +46 501 39 33 40
Fax: +46 501 39 33 41
E-mail: [email protected]
www.exhausto.se

EXHAUSTO Inc.

1200 Northmeadow Parkway
Suite 180
Roswell, GA 30076 USA
Tel.: +1 770 587 3238
Fax: +1 770 587 4731
E-mail: [email protected]
www.us.exhausto.com

6.

Technical data

EFC control:

Dimensions: 

85 mm x 126 mm x 32 mm

Supply voltage: 

230 V ± 10% / 50 Hz

Fuses : 

3,15 A T

Release out : 

Max. 3,15 A 250 VAC / 3,15A 30 VDC

Step 2 out : 

Max. 5 A 250 VAC / 5A 30 VDC

Chimney fan output :

Max. 1.8 A/230 V (AC3)

Air inlet : 

24 VDC (Closed-circuit supply)

External start : 

24 VDC (Closed-circuit supply)

Degree of protection :  IP 30

Material : 

ABS box

Ambient temperature :  -10 °C to 40 °C

External IR sensor: Cable:

10 m

IR-remote control:

Battery type :

Size AAA 1,5 V (3 pcs.)

Ambient temperature : 0 °C to 40 °C

CE Approval:

The EFC control complies with the essential requirements of the

Gas Appliances Directive (90/396/EEC).

The compliance is based on examination to: EN298 (1993), PIN: 0063BN1144

Summary of Contents for EFC 25

Page 1: ...EXHAUSTO A S Odensevej 76 DK 5550 Langeskov Tlf 45 65 66 12 34 Fax 45 65 66 11 10 exhausto exhausto dk www exhausto com EXHAUSTO 3001736 2004 01 21 fm Installation operating instructions EFC 25 GB...

Page 2: ...ut this manual to bring attention to the presence of potential hazards or important information concerning the product DANGER Indicates an imminently hazardous situation which if not avoi ded will res...

Page 3: ...fan will immediately start up on full speed When the fail safe supervision confirms sufficient chimney draught the fireplace will be lit and the fan speed will adjust to the pre set value correspondi...

Page 4: ...spare fuse included in control box M Terminals for Step 2 E PDS pressure differential switch terminals N Terminals for start signal to fireplace control F Terminals for chimney fan O Terminals for fre...

Page 5: ...les on the sides of the front cover The front cover can then be tipped carefully and the frame can be mounted on the wall Notice The front cover is mounted with a connection ribbon cable in the right...

Page 6: ...e disconnected by means of a voltage free contact Connect the earth wires between power supply and chimney fan Connect the chimney fan and pressure switch to terminals 1 5 Connect the start release si...

Page 7: ...ontact Connect the earth wires between power supply and chimney fan Connect the chimney fan and pressure switch to terminals 1 5 Connect the external ON OFF switch to terminals 8 9 Connect the start r...

Page 8: ...passed Open control panel Press ON OFF button Fig 1 C Wait until constant green light if the fire has to be lit during commissioning Press the service mode button Fig 1 H on reverse of front cover The...

Page 9: ...connected the operation LED changes to GREEN Set the PDS to 10 Pa below the registered value of disengagement Press the ON OFF button Fig 1 C and the control turns off the service mode Check the star...

Page 10: ...the fireplace will get a signal to fire To stop the fire and fan press the ON OFF button fig 10 F Operation from external ON OFF switch The ON OFF switch can be used for start stop and reset of the co...

Page 11: ...Check settings and redo commissioning Flashing YELLOW No signal from air inlet 1 Re connect loop on terminal 10 11 FlashingRED GREEN or YELLOW Flashing RED Service mode on 1 Press ON OFF button No re...