background image

8

EN

PRODUCT INFORMATION 

1. MATERIALS:

the radiator is made of low-carbon steel, its surface is powder coated or chrome plated.

2. TECHNICAL PARAMETERS:

detailed product data can be found on the last page of this booklet.

3. INTENDED USE:

heating the interiors with normal air humidity and without any corrosive factors (this also applies 

to bathrooms, kitchens etc.). The powder coated version of the radiator can also be used 

as a dryer for towels and clothes.

CAUTION!

 Drying towels or clothes on the chrome plated version is not allowed.

4. RADIATOR INSTALLATION ZONES:

Zone X stands for a water source (meaning any sink, shower, bathtub or toilet). Zone A includes 

the space directly above zone X as well as 1 m to the left and 1 m to the right. If the radiators are 

to be installed in zone A they need to have an additional epoxy coating offered at extra cost by the 

Supplier. Installing a radiator without the epoxy coating in zone A will void the warranty. Zone B is 

safe for installation of steel radiators with standard coating.

We recommend having the radiators installed by an installation professional.

5. WATER QUALITY:

the radiator is intended for use in sealed central heating systems. 

CAUTION!

 The radiator must not be installed in open-vented or domestic hot water systems.

Remember to bleed your central heating system and the radiator.

The radiator is intended for use in central heating systems consisting of carbon

steel pipes or plastic pipes with diffusion barrier.

1 m

A

A

B

1 m

1 m

1 m

1 m

X

X

Summary of Contents for GREX.HO121.GR

Page 1: ...HOROS Informacje techniczne Technical informations Technische Informationen Grzejnik Radiator Radiator...

Page 2: ...za czonej informacji technicznej szczeg lnie w zakresie nieodpowiednich parametr w wody ci nienia wewn trz grzejnika oraz innych wykazanych w wymogach bezpiecznego u ytkowania c powsta e z winy Klien...

Page 3: ...MONTA U GRZEJNIK W Strefa X oznacza r d o wody umywalk prysznic wann toalet itp Strefa A obejmuje przestrze nad stref X oraz po obu jej stronach w odleg o ci do 1 m Dla utrzymania warunk w gwarancji...

Page 4: ...ni cia ewentualnych obra e cia a lub uszkodze mienia 2 W zak adanym miejscu monta u powinny znajdowa si kr ce do przy czenia grzejnika do sieci C O o rozstawie zgodnym z dokumentacj grzejnika dodatkow...

Page 5: ...e ubytk w czynnika grzewczego ciecz o nieodpowiednich parametrach r wnie mo e prowadzi do uszkodzenia SYTUACJE AWARYJNE W przypadku dostrze enia oznak awarii grzejnika takich jak wyciek czynnika grzew...

Page 6: ...w pozycji pionowej opieraj c na jednym z naro nik w tak aby powietrze mog o w trakcie zalewania swobodnie i p ynnie uchodzi z wn trza nie wolno opiera grzejnika na ste rowniku grza ki 4 Poprzez g rny...

Page 7: ...in defiance of the requirements specified in the attached technical informations in particular those regarding water characteristics pressure inside the radiator and others indicated in the requiremen...

Page 8: ...des the space directly above zone X as well as 1 m to the left and 1 m to the right If the radiators are to be installed in zone A they need to have an additional epoxy coating offered at extra cost b...

Page 9: ...fications section Additional information can be obtained from our Trading Partners 3 We recommend the use of valves on the supply and the return of the radiator 4 When converting the radiator into an...

Page 10: ...aving unsuitable chemical properties can also bring about radiator damage FAILURE SITUATIONS In case of any signs of a radiator fault such as a leak of the heating medium excessive pressure manifested...

Page 11: ...ser s manual prepared for the heater 3 Place the radiator in vertical position supporting it on one corner so that air while filling in could be released freely and continuously from the interior do n...

Page 12: ...12 RU 1 Excellent SA 2 3 a 8 RAL b 8 c 3 d 2 4 5 a b c 6 7 8 9 14 10 11...

Page 13: ...13 RU 1 2 3 4 X A X 1 1 A B 5 1 m A A B 1 m 1 m 1 m 1 m X X...

Page 14: ...14 RU 6 Nr 305 2011 9 2011 EN 442 1 1 EN 442 2 2 1 2 3 4 1 2...

Page 15: ...15 RU 3 4 5 5 6 7 a b 1 2 3...

Page 16: ...16 RU 65 C 1 2 2 3 4 3 5 90 5 6 1 7 8...

Page 17: ...iner nicht den in technischen Informationen beschrieben Um die entsprechende Anwendung von vor allem Geeignete Wasserparameter der Druck in dem K hler und andere Anforderungen f r die sichere Anwendun...

Page 18: ...MONTAGEZONEN F R HEIZK RPER Zone X ist die Wasserquelle Waschbecken Dusche Badewanne WC etc Die Zone A umfasst den Raum oberhalb der Zone X sowie auf beiden Seiten in einem Bereich von jeweils 1 m Be...

Page 19: ...tage des Heizk rpers zur Vermeidung eventueller Verletzungen oder Sachbesch digungen 2 An dem vorgesehenen Montageort sollte ein geeigneter Anschluss f r die Verbindung mit der Zentralheizung vorhande...

Page 20: ...lit t des Heizmediums falscher pH Wert oder Sauerstoffgehalt k nnen zu Korrosion f hren der Anschluss des Heizk rpers an eine Nutzwasserleitung oder das Erg nzen des He izmediums durch Fl ssigkeit mit...

Page 21: ...Heizk rper in der senkrechten Position stellen auf einer der Ecken st tzen damit die Luft w hrend des Nachf llvorgangs ungehindert von innen entweichen kann Heizk rper am Heizung sregler nicht st tze...

Page 22: ...POD CZENIA CONNECTION VERBINDUNG Z1 Z1 Z8 Z8 ZS ZS SX ZX ZX ES ZS C2 57 65 G1 2 G1 2 B D 72 80 100 E 10 C1 2xG1 2 41 49 ZX C2 57 65 G1 2 G1 2 A B D 72 80 100 E 10 C1 2xG1 2 C1 2xG1 2 41 49 41 49 ZX...

Page 23: ...roduktcode 960 500 50 470 523 418 224 GREX HO96 WH 960 500 50 470 523 418 224 GREX HO96 GR 1210 500 50 470 645 516 276 GREX HO121 WH 1210 500 50 470 645 516 276 GREX HO121 GR 1460 500 50 470 770 615 3...

Page 24: ...abstand PL Roz staw RU 7 EN Serial Number DE Seriennummer PL Numer seryjny RU 8 EN Delta T50 C Heat Output DE Heizleistung dT50 PL Wydajno dT50 RU dT50 9 EN Thermal Characteristic Equation DE Gleichun...

Reviews: