background image

 

03004035                                                                                  1                                                                    ZSME200000058 

EXCELL PRECISION CO., LTD. 

   

 

 

Table of Content

 

Indicator Housing ......................................................................................................................... 3 

Instruction for Use ........................................................................................................................ 4 

Preparations before Using ........................................................................................................... 4 

Chapter 1 Introduction.................................................................................................................. 6 

1-1 Features ............................................................................................................................. 6 

1-2 Power Supply ..................................................................................................................... 6 

1-3 Display ............................................................................................................................... 6 

1-4 Keypad ............................................................................................................................... 7 

1-5 Error Messages .................................................................................................................. 8 

Chapter 2 Operation .................................................................................................................... 9 

2-1 Power On ........................................................................................................................... 9 

2-2 Relatively Internal Value Display ........................................................................................ 9 

2-3 Zero Function ..................................................................................................................... 9 

2-4 Sampling Function .............................................................................................................. 9 

2-4-1 Unknown Unit Weight of a Weighed Object ................................................................. 9 

2-4-2 Known Unit Weight of a Weighed Object ................................................................... 10 

2-4-3 Under Tare Status ...................................................................................................... 10 

2-5 Tare Function Operation ................................................................................................... 11 

2-6 Pre-tare Function Operation ............................................................................................. 11 

2-7 Accumulation .................................................................................................................... 12 

2-7-1 Quantity Accumulation ............................................................................................... 12 

2-7-2 Weight Accumulation ................................................................................................. 13 

2-8 Quantity Preset ................................................................................................................ 14 

2-9 Weight Preset ................................................................................................................... 14 

2-10 Unit Weight Preset ......................................................................................................... 15 

Chapter 3 External Calibration Setting ....................................................................................... 16 

3-1 External Function Setting 

 

           

 

 

 ................................................................. 16 

3-1-1 Backlight Mode Setting 

 

 

           

 

 .............................................................. 17 

3-1-2 Auto. Power-off Setting 

 

 

           

 

 .............................................................. 17 

3-1-3 Stable Range Setting for Quantity Sampling 

 

 

           

 

 ............................. 18 

3-1-4 Auto. Average Unit Weight Setting 

 

 

           

 

 ............................................ 18 

3-1-5 A/D Sampling Speed Setting 

 

 

           

 

 ..................................................... 19 

3-1-6 Zero Display Range Setting 

 

 

           

 

 ...................................................... 19 

3-1-7 Zero Tracking Range Setting 

 

 

           

 

 ..................................................... 20 

3-1-8 Accumulation Ending Mode Setting 

 

 

           

 

 ........................................... 20 

Summary of Contents for PCH3

Page 1: ...herein is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissi...

Page 2: ......

Page 3: ...ighed Object 10 2 4 3 Under Tare Status 10 2 5 Tare Function Operation 11 2 6 Pre tare Function Operation 11 2 7 Accumulation 12 2 7 1 Quantity Accumulation 12 2 7 2 Weight Accumulation 13 2 8 Quantit...

Page 4: ...in Local or in Verification 26 3 3 RS 232 and Serial Printer Setting 28 3 3 1 Baud Rate Setting 28 3 3 2 Communication Protocol Setting 29 3 3 3 Output Data Format Setting 29 3 3 4 Output Count Setti...

Page 5: ...rately followed to ensure the IP rating is maintained in service There are no user serviceable parts inside the indicator and all service work should be carried out by the technical staff of your supp...

Page 6: ...e a separate power socket if possible when re charging the indicator 4 For maximum stability and accuracy switch on the indicator for 15 20 minutes before operation 5 Once the scale has been powered o...

Page 7: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Page 8: ...n 5V DC 1 2 Power Supply Power Supply Internal 6V 4 5Ah rechargeable battery AC 120 VAC to 9 VDC 1A plug top power supply AC 230 VAC to 9 VDC 1A plug top power supply Power Consumption Approximately D...

Page 9: ...mall however this may affect the counting inaccuracy Please use the scale which the division and specification are both subject to If symbol displays scale may cause some counting error even if the sc...

Page 10: ...s a warning sound Or use this key to confirm the setting Totalizing the quantity or weight Clear the stored totalizing memory Or shift the digit pointer to right Turn on or turn off the scale 1 5 Erro...

Page 11: ...e 2 3 Zero Function While operating the scale zero may sometimes fluctuate Slight weight changes happen in weight column Press Z key to return to zero 2 4 Sampling Function 2 4 1 Unknown Unit Weight o...

Page 12: ...ty column will flash 6 seconds If the user doesn t press the SMPL key before flashing is over the scale will complete the unit weight setting procedure automatically after flashing The scale will also...

Page 13: ...bol will disappear Mode 2 After removing the object together with packaging container weight column will display the negative value of packaging container Press Z key again to cancel the tare and retu...

Page 14: ...the packaging container Press T key once again to cancel the pre tare value and return to zero Then the tare and pre tare symbol will disappear Recall Pre tare value 1 Press Q TY PST key and then pres...

Page 15: ...n the memory and then accumulation symbol will disappear 2 7 2 Weight Accumulation 1 Place an object on platter when unit weight displays 0 stable Weight of the object on platter 2 Press M key 3 After...

Page 16: ...t To clear the pre set upper limit of quantity or weight please follow the above mentioned operation steps When entering the pre set value please enter 0 instead When switching to weight preset mode o...

Page 17: ...1 Pre set Unit Weight Operation Read in Use number keys to enter the unit weight The value is 0 or blank without setting Press U W PST key Press U W PST key again Press number keys to select 1 of 50 a...

Page 18: ...ss T key Press T key Press T key External Function Setting External Weight Calibration and G Value Calibration RS 232 and Serial Printer Setting Exit the Setting 1 1 Exit 1CE Move cursor leftward 1 T...

Page 19: ...g any key backlight be turned on automatically The backlight is turned off automatically when the scale is idle for 10 minutes d division No backlight When turning on the backlight mode is the same as...

Page 20: ...r value makes the sampling faster but less accurate The smaller value makes the sampling slower but more accurate It can t be shifted after sampling only when the unit weight is cleared in Brazil vers...

Page 21: ...le 3 1 6 Zero Display Range Setting Press MC key Enter parameter 00 03 Press MC key to save the setting When CFN 01 00 01 the default setting is When CFN 01 00 04 the default setting is Display all Ze...

Page 22: ...r 1 second it could track 1 2 d After weight keeps stable for over 1 second it could track 1 d After weight keeps stable for over 1 second it could track 2 d d division Only when gross 0 zero tracking...

Page 23: ...latter Enter value in UNIT WEIGHT and press T key Pre tare value can not be more than max weighing value or first and second segment point of division besides the value can not be less than or equal t...

Page 24: ...C key to save the setting Default Setting Only when the weight returns to zero the scale accepts the next accumulation value If the weight is near zero band please adjust the setting in The weight is...

Page 25: ...ins 2 functions Unit switching 50 sets for unit weight preset Press MC key Enter parameter 00 01 Press MC key to save the setting Default setting Press the combination key once to select unit priority...

Page 26: ...T Move cursor rightward 1MC Enter 3 2 External Weight and G Value Calibration Press MC key Enter parameter 00 03 After entering parameter 00 press MC key to return to previous level Return to previous...

Page 27: ...emove weight to test After testing press MC key to complete external weight calibration If no temperature IC notMP displays in UNIT WEIGIH kg No weight display Internal value Press key to quit zero ca...

Page 28: ...value is the reaction of centrifugal force for free falling object Standard G value for equator on earth surface GE 978 03184558 cm sec2 9 7803184558 m sec Standard G value for polar region Gp 983 21...

Page 29: ...G value Press MC key to enter revising mode Press key to quit and back to previous level Display previous revised times and the revised local G value Press MC key to enter revising mode Press key to q...

Page 30: ...00 bit sec 1 200 bit sec 2 400 bit sec 4 800 bit sec 9 600 bit sec 19 200 bit sec If there is free form device it is 9600 bits sec transmit Return to previous level Baud rate setting Communication pro...

Page 31: ...3 Output Data Format Setting Press MC key Enter parameter 00 09 Press MC key to save the setting Default Setting Fixed format 1 Fixed format 1 details see following page Fixed format 2 details see fol...

Page 32: ...tinuous or automatic transmission some content printed out is meaningless Fixed format 3 Press M key to print Fixed format 4 continuous or auto transmission NO 1 N W 0 500 N W 0 500 U W 1 00013 U W 1...

Page 33: ...e of continuous transmission mode If parameter in is set as it is capable of continuous transmission mode 3 3 5 Operation Mode Setting Press MC key Enter parameter 00 05 Press MC key to save the setti...

Page 34: ...left reserved LF 0x0A line feed For example Gross 0 500 kg Tare 0 150 kg Pre tare 0 050 kg Net 0 300 kg UW 0 5g PCS 600 F R 5 2 0 P LF LF SP 0 5 0 0 LF SP 0 1 5 0 LF SP 0 0 5 0 LF SP 0 3 0 0 LF SP 0...

Page 35: ...SP SP SP SP 3 LF SP 2 3 9 5 LF SP 2 3 9 3 7 LF 0 0 0 0 0 3 0 0 2 3 9 5 0 2 3 9 3 7 LF P 1 1 LF LF 0x0A line feed SP 0x20 Blank 3 3 6 Continuous Transmission Output Condition Setting Press MC key Enter...

Page 36: ...9 Press MC key to save the setting Default Setting External value 5d External value 0d External value 1d External value 99d The range setting in is related to accumulation acceptable condition in 3 3...

Page 37: ...d pre tare simple RU Read unit weight simple RD Read accumulated quantity simple RC Read accumulated counts simple Rl Read tare simple Rf Read pre set name ITEM Rk Read accumulated weight simple accum...

Page 38: ...me SP SP SP SP SP SP SP A P P L E Totally 14 bytes including CR LF Simple Format Read current weighing unit 0 CR LF Read current price computing unit 1 Read current unit weight unit 2 Totally 3 bytes...

Page 39: ...n Line Description SCALE RS 232 PRINTER SCALE PC DB 9 DB 9 DB 9 DB 9 2TX 3TX 2TX 2TX 3RX 2RX 3RX 3RX 5GND 5GND 5GND 5GND Serial Data Transfer Receive Format LSB MSB 1 0 n 8 1 S 8 bit data STOP 1 0 e 7...

Page 40: ...H b 62H 1 31H C 43H c 63H 2 32H D 44H d 64H 3 33H E 45H e 65H 4 34H F 46H f 66H 5 35H G 47H g 67H 6 36H H 48H h 68H 7 37H I 49H i 69H 8 38H J 4AH j 6AH 9 39H K 4BH k 6BH 0DH L 4CH l 6CH M 4DH m 6DH N...

Page 41: ...04035 39 ZSME200000058 EXCELL PRECISION CO LTD Appendix 4 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y...

Reviews: