03004035 20 ZSME200000058
EXCELL PRECISION CO., LTD.
Previous setting
Previous setting
1
1
Exit
1
CE
Move cursor leftward
1
T
Move cursor rightward
1
MC
Enter
3-1-7 Zero Tracking Range Setting
Press
MC
key
Enter parameter 00~03
Press
MC
key to
save the setting
When CFN 01 = 00 ~ 01, the default setting is
.
When CFN 01 = 00 ~ 04, the default setting is
.
After weight keeps stable for over 1 second, it could track
1/4 d.
After weight keeps stable for over 1 second, it could track
1/2 d.
After weight keeps stable for over 1 second, it could track
1 d.
After weight keeps stable for over 1 second, it could track
2 d. (d=division)
Only when gross = 0, zero tracking function is activated.
3-1-8 Accumulation Ending Mode Setting
Press
MC
key
Enter parameter 00~02
Press
MC
key to
save the setting
Default Setting:
Press
M+
key. After screen displays accumulation
value for 3 seconds, scale returns to weighing mode.
Press
M+
key. And screen displays accumulation
value, scale does not return to weighing mode until
pressing
CE
key
.
Press
M+
key. And screen does not display
accumulation value, but beeper beeps once.
Summary of Contents for PCH3