![Exalt ExtendAir eMIMO r5050 Series Quick Start Manual Download Page 5](http://html.mh-extra.com/html/exalt/extendair-emimo-r5050-series/extendair-emimo-r5050-series_quick-start-manual_2448774005.webp)
ExtendAir® eMIMO™ Digital Microwave Radios
208398-002
4
2014-01-07
Source (UPS) or other form of battery-backed system protects against brownout
and black-out conditions, and condition the power presented to the adapter.
1.
Connect the straight-wired outdoor rated CAT5e or CAT6 cable to the
PoE/ETH1 connection on the radio side, and then to the DATA+POWER or
OUTPUT port connection of the power injector.
2.
Connect the network Ethernet connection to the DATA or INPUT port
connection of the power injector.
3.
Mount and ground the PoE injector, as necessary.
4.
Apply appropriate AC or DC power (with proper current rating) to the input
connector of the power injector.
Configuration Overview
It is strongly advised to configure the radio system prior to physical installation.
This step minimizes total installation time and aids troubleshooting that may be
required during commissioning.
For proper communication, one radio terminal must be configured as Radio A
(radios are configured as Radio B at manufacture). Other configurations are
required before installation is complete. Use the Exalt browser-based GUI for
configuration.
Connect a CAT5e or CAT6 cable to the DATA
connector on the power injector
using either a straight or crossover cable meant for Ethernet connections.
Connect the opposite end of this cable to the management computer’s Ethernet
port. Use a browser to launch the Exalt GUI on the radio.
The computer accessing the Exalt GUI must match the IP subnet of the radio.
The radio’s default IP address is
10.0.0.1.
Since all radios are configured with
the same IP address at manufacture, change at least one radio’s IP address to
avoid an IP address conflict. Use the following procedure:
1.
Change the IP address of the accessing computer to match the radio’s
subnet.
2.
Select the Ethernet network adapter, and then select TCP/IP properties.
3.
Select the static IP address option
and change the IP address to
10.0.0.
x
(where
x
does not equal 1
or any other address planned for
either radio).
Using the GUI
A browser is required to access the GUI. Microsoft Internet Explorer 5.0 or
greater is recommended (IE 10 and above may require setting compatibility
Note:
In the GUI, press the
Shutdown
button before removing power
from the radio. This preserves the settings in radio memory.