background image

Safety

 

English 

 

 

 

 

Definitions: Safety instructions

 

 

The definitions below describe the level of severity for 
each signal word. Please read the manual and pay 
attention to these symbols 

DANGER

: Indicates an imminently hazardous 

situation which, if not avoided, will result in serious 
injury or in extreme cases a fatality 

WARNING

: Indicates a potentially hazardous 

situation which, if not avoided, could result in serious 
injury or in extreme cases a fatality 

 

CAUTION: 

Indicates a potentially hazardous 

situation which, if not avoided, may result in minor or 
moderate injury.

 

 

 NOTICE: 

Indicates a practice not related to 

personal injury which, if not avoided, may result 
in property damage. 

 Denotes risk of electric shock. 

 

Symbols found on the machine. 

 

 

Use ear protection. 

 
 

 

Use gloves. 

 

 

 

Read instructions before use

 

 

Laser radiation:

 Do not look directly into beam. 

 

 

Saw blade:

 Saw blade behind this cover, do not insert 

fingers or other body parts inside this cover.

 

Operating, safety and service 
instructions 

Read these operating, safety and service 
instructions carefully before operating the pipe saw. 

Store these instructions in a place where all pipe 
saw operators have access. In addition to these 
instructions official work, health and safety rules 
must be followed. Exact PipeCut is for professional 
use only. 

 

Please notice the article number on the type plate of 
your machine. The trade names of the individual 
machines may vary.  

Only for power tools without reduced starting current: 
Starting cycles generate brief voltage drops. 
Interference with other equipment/machines may occur 
in case of unfavorable mains system conditions. 
Malfunctions are not to be expected for system 
impedances below 0.36 ohm.  

Noise/vibration Information 

The vibration emission level given in this information 
sheet has been measured in accordance with a 
standardized test given in EN62481-2-5:2014 

Use ear protection! 

Vibration level values

 

(sum of vectors of three 

directions) are defined in accordance with standard 
EN62841-2-5:2014:  
Vibration rate a

h

 = 2,8 m/s ²,   

Uncertainty

 

K = 0,3 m/s². 

 
The vibration emission level given in this information 
sheet has been measured in accordance with a 
standardized test given in EN62841-2-5:2014 and may 
be used to compare one tool with another. It may be 
used for a preliminary assessment of exposure. 

 

WARNING

: The declared vibration emission 

level represents the level during main applications of 
the tool. 

However, if the tool is used for different applications, 
with different accessories or poorly maintained, the 
vibration emission may differ. This may significantly 
increase the exposure level over the total working 
period. 

An estimation of the level of exposure to vibration 
should also take into account the times when the tool is 
switched off or when it is running but not actually doing 
the job. This may significantly reduce the exposure 
level over the total working period. 

Identify additional safety measures to protect the 
operator from the effects of vibration such as: maintain 
the tool and the accessories, keep the hands warm, 
organize work patterns. 

 

WARNING:

 

If Pipecut Exact PipeCut 220 INOX Series tool is used 
with generator or extension cords, their minimum 
requirements are as follows:  

Generator: minimum power of 3500 watts, if other 
electrical equipment is not used at the same time. 

Extension cords 230 V: The maximum length - 25 
meters. Cable cross section - not less than 1,5mm ². 

Extension cords 120 V: The maximum length – 82

 

Feet 

Extra Heavy Duty 

 

 

 

Summary of Contents for PipeCut 220 INOX Series

Page 1: ...are the original instructions All instructions are available on web site exacttools com manuals Patents US 7 257 895 JP 4010941 EP 1301311 FI 108927 KR 10 0634113 EN Operating Instructions PipeCut 22...

Page 2: ...Intentionally left blank...

Page 3: ...for cutting Cast or Ductile Iron only Exact DIAMOND X discs cannot be sharpened Declaration of Conformity We declare under our sole responsibility that the pipe cutting machines Exact PipeCut 220 INO...

Page 4: ...8 Cutting depth adjusting wheel 9 Eccentric adjusting wheel 10 Handle 11 Blade guard screw 12 Blade lock pin 13 Rating plate 14 Motor unit 15 Blade RPM selector switch 16 Motor unit adjustment indica...

Page 5: ...0 Piercing the pipe wall 11 Cutting around the pipe 11 Overload protection and RPM adjustment 13 Explanation if indicator lights 13 Improving possible misalignment of the cut 13 Cutting result adjustm...

Page 6: ...Ah 2 8 m s2 Vibration uncertainty K 0 3 m s2 LpA sound pressure 98 2 dB A KpA sound pressure uncertainty 3 dB A LWA acoustic power 109 7 dB A KWA acoustic power uncertainty 3 dB A Recommended generato...

Page 7: ...are not to be expected for system impedances below 0 36 ohm Noise vibration Information The vibration emission level given in this information sheet has been measured in accordance with a standardized...

Page 8: ...nintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch...

Page 9: ...ligned saw blade causing an uncontrolled saw to lift up and out of the workpiece toward the operator when the blade is pinched or jammed tightly by the kerf closing down the blade stalls and the motor...

Page 10: ...me wet When you use the saw the following factors shall be considered Support the pipes to be cut properly so that the blade is not clamped between the ends of the pipes Support the pipe to cut secure...

Page 11: ...pipe Check that all support wheels contact the pipe adjust if required e g with pieces of lumber FIGURE B1 When cutting short and light weight pipes place the supports so that the cutting point is ou...

Page 12: ...through the pipe wall during piercing the pipe must not rotate Look at the UNLOCK SWITCH during the piercing operation The yellow mark on UNLOCK SWITCH disappears FIGURE E 1 2 when the pipe saw is lo...

Page 13: ...rrect function of blade cover When the pipe is cut off push the UNLOCK SWITCH forward until the yellow mark is visible and the locking is released FIGURE I1 1 2 Now raise the motor unit to starting po...

Page 14: ...codes To be able to read the codes the main switch needs to be kept connected List of error codes can be found below No of blinks Error description 1 Mains frequency too high 2 Mains frequency too lo...

Page 15: ...ng Loosen the two screws securing the bodyplate FIGURE N 2 Turn the bodyplate to the required direction and secure the two screws Make only small adjustments at a time If the cutting line goes from ri...

Page 16: ...cutting depth by turning the adjustment wheel For higher setting smaller cutting depth turn the adjustment wheel counter clockwise FIGURE P 1 For lower setting deeper cutting depth turn the adjustmen...

Page 17: ...ing or cleaning the pipe saw All maintenance operations carried out on the pipe saw s electrical components must be carried out by an approved service center or engineer Blade Check the condition of t...

Page 18: ...the operating safety and servicing instructions provide in these instructions 5 The Exact PipeCut Saw has been delivered to an Authorized Warranty Repair Center within the warranty period NOTICE The E...

Page 19: ...Intentionally left blank...

Page 20: ...l user knowledge Cleanliness of the pipe Pipe circumference Too loose or tight gripping device Too tight blade Maximum recommended pipe wall thicknesses of different materials which can be cut by Exac...

Reviews: