Design and function
Select welding task
40
099-000097-EW501
14.03.2012
5.7.8
Pulse variants
NOTE
The machines have an integrated pulse device.
With pulses, the machine switches back and forth between the pulse current (main
current) and pause current (secondary current).
Pulses (thermal pulses)
With thermal pulses, the pulse and pause times (frequency up to 200 Hz) and the pulse edges (ts1 and
ts2) are entered in seconds on the control.
Figure 5-17
Operating
element
Action Result
Display
Select TIG pulses function
Signal light comes on in green
-
Select pulse time "t1"
LED "Pulse time" comes on
Set pulse time "t1"
Select pause time "t2"
LED "Pulse pause time" comes on
Set pause time "t2"
2 s
Select slope times "ts1 and ts2"
Set slope time "ts1"
Change between slope times "ts1 and ts2"
Set slope time "ts2"