Design and function
Select welding task
30
099-000097-EW501
14.03.2012
5.7.2
Save welding tasks (JOBs)
You can select, change and save the required welding parameters for recurring welding tasks (JOBs) in
up to 7 JOBs (JOB 1 to JOB 7).
5.7.2.1
Displaying and changing the JOB number
Operating
element
Action Result
n x
Select JOB display
Change the JOB number
1 x
If the display switchover is pressed or if there is no keyboard input for 5
seconds, the new JOB will be active
NOTE
The procedure for setting welding tasks is the same as described under "Manual,
standard operation (JOB 0)". A JOB can only be switched if no welding current is
flowing.
The up-slope and down-slope times can be set separately for non-latched and latched.
5.7.3
Welding data display
The following welding parameters can be displayed before (nominal values) or during (actual values)
welding.
Parameter Before
welding
(nominal values)
During welding
(actual values)
Welding current
;
;
Welding voltage
;
JOB number
;
Parameter times
;
Parameter currents
;
;
possible
not possible
5.7.3.1
Welding parameter setting
The parameters that can be set in the function sequence of the machine control depend on the selected
welding task. This means that if for example you have not selected a pulse variant, then you cannot set
any pulse times in the function sequence.