Design and function
Menus and sub-menus on the machine control
64
099-000097-EW501
14.03.2012
5.14
Menus and sub-menus on the machine control
5.14.1
Direct menus (direct access to parameters)
Functions, parameters and their values can be accessed directly, e.g. can be selected by pressing a
button once.
5.14.2
Expert menu (TIG)
The expert menu includes functions and parameters which are either not set on the machine control, or
which do not require regular setting.
Figure 5-33
Display Setting/selection
Expert menu
Slope time tS1 (main current to secondary current)
Setting: 0.00 s to 20.0 s (factory setting 0.01 s)
Slope time tS2 (secondary current to main current)
Setting: 0.00 s to 20.0 s (factory setting 0.01 s)
activArc parameter
Parameter can also be set after activating TIG activArc welding.
Display shown = factory setting.
NOTE
ENTER (enter the menu)
• Keep the "welding parameters" button pressed for 4 s.
Navigating in the menu
• Parameters are selected by pressing the "welding parameters" button.
• Set or change the parameters by turning the "welding parameter setting" rotary dial.
EXIT (leave the menu)
• After 4 s, the machine will return automatically to the ready-to-operate status.