Design and function
System gas connection
30
099-008724-EW501
08.01.2012
1
2
Figure 5-2
Item Symbol Description
0
1
G1/4" connecting nipple, shielding gas connection
Connection to the pressure reducer
2
G1/4" connecting nipple, plasma gas connection
Connection to the pressure reducer
• Screw the connection coupling of the plasma gas line onto the G1/4" connecting nipple, plasma gas
connection.
• Screw the connection coupling of the shielding gas line onto the G1/4" connecting nipple, shielding
gas connection.