Rectifying faults
Warnings
099-005664-EW501
22.09.2021
41
Warning
Possible cause / remedy
8
Welding circuit
The welding circuit inductance is too high for the selected
welding task.
9
WF configuration
Check WF configuration.
10
Partial inverter
One of several partial inverters is not supplying welding current.
11
Excess temperature, coolant
[1]
Check temperature and switching thresholds.
[2]
12
Welding monitor
The actual value of a welding parameter is outside the specified
tolerance field.
13
Contact error
The resistance in the welding circuit is too high. Check earth
connection.
14
Adjustment error
Switch the machine off and on. If the error persists, notify Ser-
vice.
15
Mains fuse
The power limit of the mains fuse is reached and the welding
power is reduced. Check the fuse setting.
16
Protective gas warning
Check the gas supply.
17
Plasma gas warning
Check the gas supply.
18
Forming gas warning
Check the gas supply.
19
Gas warning 4
reserved
20
Coolant temperature warning Check coolant level and top up if necessary.
21
Excess temperature 2
reserved
22
Excess temperature 3
reserved
23
Excess temperature 4
reserved
24
Coolant flow warning
Check coolant supply.
Check coolant level and top up if necessary.
Check flow and switching thresholds.
[2]
25
Flow 2
reserved
26
Flow 3
reserved
27
Flow 4
reserved
28
Wire stock warning
Check wire feeding.
29
Low wire 2
reserved
30
Low wire 3
reserved
31
Low wire 4
reserved
32
Tacho error
Fault of wire feeder - permanent overload of the wire drive.
33
Wire feed motor excess current Excess current detected on wire feed motor.
34
JOB unknown
JOB selection was not performed because the JOB number is
unknown.
35
Wire feed motor slave excess
current
Excess current detected on wire feed motor slave (push/push
system or intermediate drive).
36
Slave tacho error
Fault of wire feeder - permanent overload of the wire drive
(push/push system or intermediate drive).
37
FAST-bus failure
Wire feeder not connected (reset by actuating the automatic
cutout of the wire feed motor).
38
Incomplete component informa-
tion
Check XNET component management.
39
Mains half-wave failure
Check supply voltage.