Design and function
MIG/MAG welding
72
099-005231-EW501
10.05.2012
N cycle setting
NOTE
The n cycle function should always be activated before the n cycle setting (see
"Program changeover with standard torch (P8)".
m /m in
Figure 5-39
Latched/special-latched tap start (P9)
In latched – tap start – operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
Hold function (P15)
Hold function active (P15 = 1)
• Mean values for the last main program parameters used for welding are displayed.
Hold function not active (P15 = 0)
• Setpoint values for the main program parameters are displayed.