Design and function
MIG/MAG welding
099-005231-EW501
10.05.2012
73
Selecting programs with the standard torch trigger (P17)
Allows you to select a program or switch a program before starting welding.
You switch to the next program by tapping the torch trigger. Once the last enabled program is reached,
you start again at the beginning.
• Program 0 is the first enabled program, provided that it is not blocked.
(see also special parameter P2).
• The last enabled program is P15.
-
If the programs are not limited by special parameter P4 (see special parameter P4).
-
Or if the programs are limited for the selected JOB by the n cycle setting (see parameter P8).
• Welding starts when the torch trigger is held for longer than 0.64 s.
You can select programs with the standard torch trigger in all operating modes (non-latched, special non-
latched. latched and special latched).
Switching the operating mode and welding type using the wire feed control (P18)
Selection of the operating mode (non-latched, latched, etc.) at the wire feed control or the welding
machine control.
• P18 = 0
-
Program 0: Selection of the operating mode at the wire feeder.
-
Program 1–15: Selection of the operating mode at the welding machine.
• P18 = 1
-
Program 0–15: Selection of the operating mode at the wire feeder.
Software key switch (SCH)
The key switch function allows the welding machine to be locked using the software.