Machine description – quick overview
Machine control – Operating elements
099-005231-EW501
10.05.2012
23
Item Symbol Description
0
1
Lid (see chap. "Machine control – concealed operating elements")
2
Button, Parameter selection left
AMP
Welding
current
Material thickness
Wire speed
HOLD
After each completed welding process, the last parameter values used for the
welding process are shown on the display in the main program; the signal
light
is
on
3
Display, left
Welding current, material thickness, wire speed, hold values
4
m/min
Welding parameter setting, rotary dial
For setting the welding performance, for selecting the JOB (welding task) and for
setting other welding parameters.
5
Operating mode selection button
Non-latched
Latched
Signal light lights up in green: special non-latched
Signal light lights up in red: MIG spot welding
Special
latched
6
DYN
Dynamics/choke effect button
+
Arc harder and narrower
-
Arc softer and wider
7
Arc length correction/selection of welding program, rotary dial
• Correction
of the
arc length from -9.9 V to +9.9 V.
• Selection of welding programs 0 to 15 (not possible if accessory components, such
as program torches, are connected).
8
Display, right
Welding voltage, program number
9
Button, Parameter selection (right)
VOLT
Welding
voltage
PROG
Program
number
Coolant error
Temperature error