Design and function
Special parameters (advanced settings)
099-004846-EW501
8.01.2014
73
"Single or dual operation" (P10) setting
NOTE
If the system is fitted with two wire feeds, no further accessory components may be
operated on the 7-pole connection socket (digital)!
This relates to digital remote controls, robot interfaces, documentation interfaces,
welding torches with digital control lead connection, etc.
No second wire feed may be connected in single operation (P10 = 0)!
• Remove connections to the second wire feed
In dual operation (P10 = 1 or 2), both wire feed units must be connected and configured differently
on the controls for this operating mode!
• Configure one wire feed unit as the master (P10 = 1)
• Configure the other wire feed unit as a slave (P10 = 2)
Wire feed units with key switches (optional, see Protecting welding parameters from unauthorised
access chapter) must be configured as masters (P10 = 1).
The wire feed configured as the master is active after the welding machine is switched on. There
are no other functional differences between the wire feeds.
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
JOB list switching (P12)
Value Designation
Explanation
0
Task-oriented
JOB list
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
1
Actual JOB list
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
2
Actual JOB list,
JOB changeover active
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
Lower and upper limits of the remote JOB changeover process (P13, P14)
The highest and lowest JOB numbers which can be selected using accessory components, such as the
PowerControl 2 torch.
Avoids an accidental changeover into undesirable or undefined JOBs.
Hold function (P15)
Hold function active (P15 = 1)
• Mean values for the last main program parameters used for welding are displayed.
Hold function not active (P15 = 0)
• Setpoint values for the main program parameters are displayed.
Summary of Contents for Phoenix Expert drive 4L M3.70
Page 92: ...Appendix A JOB List 92 099 004846 EW501 8 01 2014 11 Appendix A 11 1 JOB List...
Page 93: ...Appendix A JOB List 099 004846 EW501 8 01 2014 93...
Page 94: ...Appendix A JOB List 94 099 004846 EW501 8 01 2014...
Page 95: ...Appendix A JOB List 099 004846 EW501 8 01 2014 95...
Page 96: ...Appendix A JOB List 96 099 004846 EW501 8 01 2014...
Page 97: ...Appendix A JOB List 099 004846 EW501 8 01 2014 97...
Page 98: ...Appendix A JOB List 98 099 004846 EW501 8 01 2014...
Page 99: ...Appendix A JOB List 099 004846 EW501 8 01 2014 99...
Page 100: ...Appendix A JOB List 100 099 004846 EW501 8 01 2014...