Design and function
Special parameters (advanced settings)
099-004846-EW501
8.01.2014
67
Display
Setting/selection
Predefined execution of the pulsed arc welding process in the PA program
1 =
If the superPuls and welding process switching functions are available and
activated, the pulsed arc welding process is always executed in the main
program PA (ex factory).
0 =
Predefined execution of the pulsed arc welding process in the PA program is
disabled.
Predefined absolute value for relative programs
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set
relative to the main program (P
A
) or in an absolute manner, as desired.
0 =
Relative parameter setting (ex factory)
1 =
Absolute parameter setting
5.12.2
Reset to factory settings
NOTE
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
Action
Result
Switch off welding machine
Keep the button pressed
Switch on welding machine
Release the button, wait about 3 seconds
Switch off welding machine and restart in order to put the changes into
effect
Summary of Contents for Phoenix Expert drive 4L M3.70
Page 92: ...Appendix A JOB List 92 099 004846 EW501 8 01 2014 11 Appendix A 11 1 JOB List...
Page 93: ...Appendix A JOB List 099 004846 EW501 8 01 2014 93...
Page 94: ...Appendix A JOB List 94 099 004846 EW501 8 01 2014...
Page 95: ...Appendix A JOB List 099 004846 EW501 8 01 2014 95...
Page 96: ...Appendix A JOB List 96 099 004846 EW501 8 01 2014...
Page 97: ...Appendix A JOB List 099 004846 EW501 8 01 2014 97...
Page 98: ...Appendix A JOB List 98 099 004846 EW501 8 01 2014...
Page 99: ...Appendix A JOB List 099 004846 EW501 8 01 2014 99...
Page 100: ...Appendix A JOB List 100 099 004846 EW501 8 01 2014...